S S e e t t u u p p M M e e n n u u
The centre section TFT screen provides access to a setup menu that holds a number of useful console-related items.
Select SSL followed by Misc and then Setup (see Section 3 if you are not familiar with the use of the TFT and its
associated soft keys).
To change a setting, use the left hand D-Pot to select the item, then press the D-Pot to enter adjustment mode. Turn
the D-Pot to the desired setting and press it a second time to save the setting to non-volatile memory.
The Setup options are as follows:
Automation
Glide frames:
Rollback threshold frames:
In Mix show:
Mix Update Mode:
Automated switches turn off on**: Select whether the off function of automatable switches is sent on
Grouping
Fader Grouping Mode:
Group Lockout level:
** Only displayed if the DualitySE software features have been enabled
D D u u a a l l i i t t y y S S E E O O p p e e r r a a t t o o r r ' ' s s M M a a n n u u a a l l
Sets the ramp time in frames for the automation SNAP mode. (range
0 - 255)
Sets the number of consecutive frames that the system needs to see
to determine if a Rollback has taken place. The range is 2 - 10; the
default is 2 frames. Increase as required if a Rollback occurs when
you stop the timecode master.
When using the automation, you have a choice of what is displayed
on the consoles channel scribble strips (and below the Group and
Master fader levels in the Centre Section TFT screen). The choices
are:
Automation Mode: displays the status of the faders – Auto, Safe or
Manual;
Channel names in Mix running: displays the channel names once
Execute is pressed in automation,
Channel names: displays the channels names regardless.
Sets the default automation mode at the start of an update mix
(Replay / Absolute / Trim).
the down-press or release of the button (Press / Release).
Selects the fader grouping mode (Servo / VCA). (See Group
Control Faders for more details).
Set the group master level below which slave faders cannot have their
balance altered (available in Servo grouping mode only). The lockout
level range is -35dB to -70dB or OFF.
C C o o n n s s o o l l e e O O p p e e r r a a t t i i o o n n s s
2 2 - - 4 4 3 3
Need help?
Do you have a question about the Duality SE and is the answer not in the manual?