Display Transceiver Diagnosis - HP A8800 Series Fundamentals Command Reference

Hide thumbs Also See for A8800 Series:
Table of Contents

Advertisement

Field
Transceiver type not supported by port hardware
Examples
# Display alarms present on the transceiver module in interface GigabitEthernet 3/1/1.
<Sysname> display transceiver alarm interface gigabitethernet 3/1/1
GigabitEthernet3/1/1 transceiver current alarm information:
RX loss of signal
RX power low
Table 28 Command output
Field
transceiver current alarm information
RX loss of signal
RX power low

display transceiver diagnosis

Syntax
display transceiver diagnosis { controller [ controller-type controller-number ] | interface [ interface-type
interface-number ] } [ | { begin | exclude | include } regular-expression ]
View
Any view
Default level
2: System level
Parameters
controller [ controller-type controller-number ]: Displays the measured values of the digital diagnosis
parameters for the transceiver module in a controller interface. The controller-type controller-number
argument specifies a controller interface by its type and number. If no controller interface is specified, this
command displays the measured values of the digital diagnosis parameters for transceiver modules in all
controller interfaces.
interface [ interface-type interface-number ]: Displays the measured values of the digital diagnosis
parameters for the transceiver module in an interface. The interface-type interface-number argument
specifies an interface by its type and number. If no interface is specified, this command displays the
measured values of the digital diagnosis parameters for the transceiver modules in all interfaces.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Remarks
Transceiver type is not supported on the port.
Description
Alarms present on the transceiver module.
Incoming (RX) signal is lost.
Incoming (RX) power level is low.
155