Display Fan - HP A8800 Series Fundamentals Command Reference

Hide thumbs Also See for A8800 Series:
Table of Contents

Advertisement

3
hotspot 1
3
hotspot 2
Table 21 Command output
Field
System Temperature information (degree centigrade)
Slot
Sensor
Temperature
Lower limit
WarningLimit
AlarmLimit
ShutdownLimit

display fan

Syntax
display fan [ fan-id ] [ | { begin | exclude | include } regular-expression ]
View
Any view
Default level
1: Monitor level
Parameters
fan-id: Displays the operating state of the specified fan tray, where fan-id represents the built-in fan tray
number.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use display fan to display the operating states of built-in fan trays.
45
-5
37
-5
143
65
85
65
85
Description
Temperature information of system cards (degree
centigrade)
A number in this field indicates a card.
Temperature sensor.
Hotspot—A hotspot sensor.
Inflow—An air intake sensor.
Outflow—An air exhaust sensor.
Current temperature.
Lower limit of temperature.
Warning temperature threshold.
Alarming temperature threshold.
Shut-down temperature threshold. When the sensor
temperature reaches this limit, the device shuts down
automatically.
N/A
N/A

Advertisement

Table of Contents
loading

Table of Contents