HP A8800 Series Fundamentals Command Reference page 129

Hide thumbs Also See for A8800 Series:
Table of Contents

Advertisement

Default level
3: Manage level
Parameters
patch-number: Specifies the sequence number of a patch. Values available for this argument depend on
the patch file that has been loaded. If no sequence number is specified, this command confirms all
ACTIVE patches and changes their state to RUNNING. If a sequence number is specified, this command
confirms the specified ACTIVE patch and all its previous patches, and changes their state to RUNNING.
slot slot-number: Specifies a card by its slot number. If no slot is specified, the command applies to all
cards.
Description
Use patch run to confirm ACTIVE patches.
This command is applicable to patches in ACTIVE state only.
After being confirmed, ACTIVE patches are set in RUNNING state and can continue to run after a reboot.
If not being confirmed, ACTIVE patches are set in DEACTIVE state at a reboot.
Examples
# Confirm patch 3 and all its previous ACTIVE patches on the MPU in slot 1.
<Sysname> system-view
[Sysname] patch run 3 slot 1
# Confirm all ACTIVE patches on the MPU in slot 1.
<Sysname> system-view
[Sysname] patch run slot 1