5. Open the reverse automatic document feeder
and remove the two screws shown in the illustra-
tion.
6. Close the reverse automatic document feeder.
7. Remove the front cover.
8. Loosen the two screws shown in the illustration.
9. Turn the adjustment dial according to the differ-
ence of the deviation.
When the difference is a positive (+) value, turn
the dial clockwise
When the difference is a negative (-) value, turn
the dial counterclockwise
A2X0IXC039DA
10. Make duplex copies and check the amount of
deviation (Z).
11. After completing the adjustment, tighten the
screws loosened in step 8.
12. Install the front cover removed in step 7. (Two
screws)
A2X0IXC040DA
A2X0IXC066DA
E-17