Anton Sprint eVo User Manual page 24

Multi-function flue gas analyser
Table of Contents

Advertisement

Specification
Gases
Range
Oxygen
0-25%
Carbon
0-5,000ppm
monoxide
(H
com-
2
pensated,
optional)
Carbon
0-25%
dioxide
(Calculated)
CO/CO2
0 to 0.9999
ratio
Nitrogen
0-1000ppm
Monoxide
(V4 & V5
only)
Other Measurements
Measurement
Temperature
(selectable ºC or ºF)
Efficiency
XSAir
Draught/Pressure Measurement
Let-by/Tightness Test
Pressure Scale
Range
Resolution
Accuracy
Equivalent scales
Communications
IR Port
USB
22
Display
Accuracy
Detection
Resolution
0.1%
± 0.2%
0.3% v/v
≤20ppm;
1ppm
±3ppm
±3ppm
>20ppm;
±3%
0.1%
±0.2% v/v
0.2% v/v
0.0001
1ppm
±5ppm
5ppm
or 5% of
reading
Range
-50º to 1100ºC (-58º to 2012ºF)
0-100% Net or Gross
0-120% Net High Efficiency
0-100%
Dedicated test and report/print structure for
combined test to IGE/11/UP/1B
-150 mbar to +150 mbar
0.1 mbar
±0.5% of reading calibration at +50 mbar
(equivalent to ±0.5 mbar)
Pa, hPa, kPa, PSI, inWG, mmWG, inHG, mmHG
Sprint eVo 1 /eVo 2 /eVo 3
Response
Recovery
limit
time
time
(t90)
50 sec
30 sec
45 sec
60 sec
50 sec
30 sec
90 sec
60 sec
Diagnostics
ü
ü

Hide quick links: