Acs880-07 Drives, Frames Nxdxt + Nxr8I - ABB ACS880-07 User Manual

Emergency stop, stop category 0 (option +q951)
Hide thumbs Also See for ACS880-07:
Table of Contents

Advertisement

14 Option description and instructions
Step
Operation
5.
Normal operation resumes after the user:
• releases the emergency stop button [S61] to normal (up) position
• resets the emergency stop circuit with the emergency stop reset button [S62]
• resets the drive.
If the drive is used in remote control mode, see firmware manual for more information.

ACS880-07 drives, frames nxDXT + nxR8i

-T22
-Q1/2
-K62.1
-A61
-S61
L
-K62.1
-Q1/2
1)
Reset circuit
A41
Control board (inverter unit)
A51
Control board (supply unit)
A61
Emergency stop safety relay
K62.1 Auxiliary safety relay
K62.2 Auxiliary relay
X969
STO terminal block
Initial status: The drive is in operation and the motor is running.
Step
Operation
1.
The user activates emergency stop by pushing the emergency stop button [S61].
2.
The emergency stop safety relay [A61] de-energizes relays [K62.1] and [K62.2].
The auxiliary safety relay [K62.1] de-energizes the main contactor [Q2].
The main contactor [Q2] switches off the power supply to the drive module [T1].
The auxiliary relay [K62.2] switches off the DIIL input of the supply unit control board [A51] and the
XSTO inputs IN1 and IN2 of the inverter unit control board [A41].
Control relays
24 V
1)
-S62
-K62.1
-K62.2
-P62
S61
Emergency stop button
S62
Emergency stop reset button
P62
Emergency stop indication lamp
Q1/2
Main contactor
T1
Drive module
T22
24 V power supply
Drive control boards
-A51
24 V
-K62.2
DIIL
-A41
XSTO
OUT
-K62.2
SGND
IN1
IN2
-X969
1-2
3-4
Main circuit
-Q1/2
-T1
M
3~