Exclusion Of Liability - ABB ACS880-07 User Manual

Emergency stop, stop category 0 (option +q951)
Hide thumbs Also See for ACS880-07:
Table of Contents

Advertisement

Abbreviation
Description
Frame (size)
Relates to the construction type of the drive in question. For example,
several drive types with different power ratings can have the same
basic construction, and a frame size is used in reference to all those
drive types.
With the ACS880-07/17/37 (smaller), the frame size marking of the
drive indicates the physical size of the drive, eg, R6.
With the ACS880-07 (larger), the frame size marking of the drive
indicates the quantity and frame size of the diode supply modules
plus the quantity and frame size of the inverter modules, eg,
"2×D8T +3×R8i".
With the ACS880-17 and ACS880-37 (larger), the frame size marking
of the drive indicates the quantity and frame size of the IGBT supply
modules plus the quantity and frame size of the inverter modules, eg,
"2×R8i +3×R8i".
HFT
Hardware fault tolerance
IGBT
Insulated gate bipolar transistor
PFD
Average probability of dangerous failure on demand
avg
PFH
Average frequency of dangerous failures per hour
PL
Performance level (levels are: a, b, c, d and e). Corresponds to SIL.
R6...R11, R8i
Frame size designation of the drive, inverter or IGBT supply module
SC
Systematic capability
SIL
Safety integrity level
SILCL
Maximum SIL that can be claimed for a safety function or subsystem EN/IEC 62061
T1
Proof test interval or lifetime (the smaller one)

Exclusion of liability

ABB is not responsible for the implementation, verification and validation of the overall
safety system. It is the responsibility of the system integrator (or other party) who is
responsible for the overall system and system safety.
The system integrator (or other responsible party) must make sure that the entire
implementation complies with all relevant standards, directives and local electrical code,
and that the system is tested, verified and validated correctly.
Introduction to the manual 9
Reference
IEC 61508,
EN/IEC 62061
IEC 61508
IEC 61508
EN ISO 13849-1
IEC 61508
IEC 61508,
IEC 61511,
EN/IEC 62061,
EN/IEC 61800-5-2
IEC 61508,
EN/IEC 62061

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs880-17Acs880-37Acs580-07Acq580-07Ach580-07

Table of Contents