Erc 21X Series; Erc 211; Erc 213; Erc 214 - Danfoss ERC 211 User Manual

Smart multipurpose refrigeration controller erc 21x series
Hide thumbs Also See for ERC 211:
Table of Contents

Advertisement

1.3|

ERC 21X Series

Three version of ERC 21X is available in both 230 V / 50/60 Hz and 115 V / 60 Hz.
– ERC 211: single relay output for refrigeration and heating applications.
– ERC 213: three relays outputs for ventilated refrigeration applications.
– ERC 214: four relays outputs for ventilated refrigeration applications.

1.3.1| ERC 211

ERC 211 has one relay output and two inputs
(1 analogue, 1 analogue/digital).
This controller can be used for either cooling or heating
applications.
Outputs:
– Relay 1: compressor/solenoid valve control or simple
heater in case of heating application Inputs.
Inputs:
– Input1: cabinet/control sensor (Sair).
– Input 2: condenser sensor or digital inputs which can
be configured for various functions as mentioned under
menu code o02.

1.3.2| ERC 213

ERC 213 has three relays outputs and four inputs
(2 analogues, 1 analogue/digital, 1 digital) for cooling
applications.
Outputs:
– Relay 1: compressor/solenoid valve control.
– Relay 2: can be configured either defrost or external alarm.
– Relay 3: fan control.
Inputs:
– Input 1: cabinet/control sensor (Sair).
– Input 2: defrost sensor (S5).
– Input 3 : condenser sensor (Sc) or digital input which can
be configured to various functions as mentioned under
menu code "o02".
– Input 4: digital input which can be configured to various
functions as mentioned under menu code "o37"

1.3.3| ERC 214

ERC 214 has four relays outputs and four inputs (2 analogue,
1 analogue/digital, 1 digital) for cooling applications.
Outputs:
– Relay 1: compressor/solenoid valve control.
– Relay 2: defrost control.
– Relay 3: fan control.
– Relay 4 : this can be configured for either light or external
alarm.
Inputs:
– Input 1: cabinet/control sensor (Sair).
– Input 2: defrost sensor (S5).
– Input 3 : condenser sensor (Sc) or digital input which can
be configured to various functions as metioned under
menu code "o02".
– Input4: digital input which can be configured for various
functions as mentioned under menu code "o37".
Sair
Sair
S5
Sair
S5
FR · ERC 21X user manual · DKRCC.ES.RL0.H3.02/520H9656 · ©Danfoss
DO1
Sc
DI1
DI2
DO1
Sc
DO2
DO3
DI1
DI2
DO4
DO1
Sc
DO2
DO3
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Erc 214Erc 213

Table of Contents