F. AIR CLEANER

Clean the Air Cleaner Element

--- every 250 hours or when the air cleaner
indicator comes ON.

Replace the Air Cleaner Element

--- after cleaning six times or after one year
Clean and replace air cleaner element.
1. Before servicing element (1), be sure to stop the
engine.
WARNING: Be sure to wear safety glasses or
goggles before removing cover (3).
2. Loosen two clamps (2) to remove cover (3) and
element (1).
WARNING: Wear safety glasses or goggles when
using compressed air pressure [less than 0.2
2
MPa (2 kgf/cm
, 29 psi)].
IMPORTANT:
Clean cover (3) to prevent dirt or water from
entering the air cleaner suction port. If water
enters the air cleaner suction port, damage to
the engine may result.
When cleaning, don't hit element (1) or force
the element to collide against other object.
3. Clean element (1) by blowing compressed air
pressure [less than 0.2 MPa (2 kgf/cm
the inside of the element. After cleaning, be sure to
check element (1) for damage. If any damage is
found, replace the element with a new one.
4. If air filter indicator (5) comes ON immediately after
cleaning the element (1) even though cleaning is less
than six times, replace the element with a new one.
5. When installing cover (3), position the cover so that
valve (4) faces downward. Then, tighten the cover
with clamps (2) in the specified position.
MAINTENANCE
5
2
, 29 psi)] from
7-41
1
2
4
2
4
ZX27U
, ZX30U
, ZX35U
-2
-2
2
5
4
ZX40U
, ZX50U
-2
-2
5
M555-07-023
3
M1M7-07-041
-2
3
2
M1M7-07-042

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zx30u-2Zx35u-2Zx40u-2Zx50u-2

Table of Contents