3. Press
"Enter" to begin calibration. The step numbers are shown on the display, starting with "Stp -1-."
Each step is described as follows:
NOTE:
a.) Verify that the inner arm is not extended, is in the "home" position, and is not moving.
Tap the foot pedal once or press "Enter."
b.) Place the calibration tool on the shaft, using the spindle shaft slot located closest to the
middle of the calibration tool, as shown. Rotate the calibration tool slowly by hand,
clockwise until there is a beep, and the step number changes to "-3-."
c.) Position the calibration tool parallel to the floor. Tap the foot pedal once or press "Enter."
d.) Place the inner Dataset® arm at upward position "1" as shown. Tap the foot pedal once
or press "Enter."
e.) Move the inner Dataset® arm to upward position "2." Tap the foot pedal once or press
"Enter."
f.) Move the inner Dataset® arm to upward position "3." Tap the foot pedal once or press
"Enter."
Turn the distance dimension knob to backup to a previous cal step.
WHEN POSITIONING THE INNER DATASET ARM,
VERIFY THAT THE INDENT OF THE ARM IS
CENTERED
ON THE BUTTON FOR EACH POSITION.
3
2
1
11