Application example
An application example of M+SF_ANTI_R is shown below.
■ Labels
• Input labels
Variable name
Allocated device/label
i_bActivate
SA\M100
i_bS_ChannelNC
SA\X1000
i_bS_ChannelNO
SA\X1001
i_dDiscrepancyTime
K100
• Output labels
Variable name
Allocated device/label
o_bReady
SA\M200
o_bS_AntivalentOut
SA\Y1000
o_bError
SA\Y1001
o_wDiagCode
SA\D1000
Description
Activation of the safety FB
Safety input signal (NC contact)
Safety input signal (NO contact)
Max. consistent time for i_bS_ChannelNC and i_bS_ChannelNO
Description
Status of whether the safety FB is activated or not.
Safety output signal
Error flag
Diagnostic code