Wrong muting sequences
Status
Wrong muting sequences
8000H
When muting sequence starts, i_bMutingEnable=OFF
(MS_11=ON OR MS_12=ON) AND (MS_21=ON OR MS_22=ON)
MS_11=OFF→ON AND MS_12=ON AND undetected MS_12=OFF→ON
MS_12=OFF→ON AND MS_11=ON AND undetected MS_11=OFF→ON
MS_21=OFF→ON AND MS_22=ON AND undetected MS_22=OFF→ON
MS_22=OFF→ON AND MS_21=ON AND undetected MS_21=OFF→ON
(MS_11=ON AND undetected MS_11=OFF→ON) AND (MS_12=ON AND undetected MS_12=OFF→ON)
(MS_21=ON AND undetected MS_21=OFF→ON) AND (MS_22=ON AND undetected MS_22=OFF→ON)
8011H
i_bMutingEnable=OFF OR MS_11=OFF OR MS_21=ON OR MS_22=ON
8311H
i_bMutingEnable=OFF OR MS_12=OFF OR MS_21=ON OR MS_22=ON
8012H
MS_11=OFF OR MS_12=OFF
8021H
MS_11=OFF→ON OR MS_12=OFF→ON
(MS_11=ON OR MS_12=ON) AND (MS_21=ON→OFF OR MS_22=ON→OFF)
(MS_11=ON→OFF OR MS_12=ON→OFF) AND (MS_21=ON→OFF OR MS_22=ON→OFF)
8014H
MS_11=OFF OR MS_12=OFF OR MS_21=OFF
8314H
MS_11=OFF OR MS_12=OFF OR MS_22=OFF
8122H
i_bMutingEnable=OFF OR MS_11=ON OR MS_12=ON OR MS_21=OFF
8422H
i_bMutingEnable=OFF OR MS_11=ON OR MS_12=ON OR MS_22=OFF
8121H
MS_21=OFF OR MS_22=OFF
8112H
MS_21=OFF→ON OR MS_22=OFF→ON
(MS_21=ON OR MS_22=ON) AND (MS_11=ON→OFF OR MS_12=ON→OFF)
(MS_11=ON→OFF OR MS_12=ON→OFF) AND (MS_21=ON→OFF OR MS_22=ON→OFF)
8114H
MS_21=OFF OR MS_22=OFF OR MS_11=OFF
8414H
MS_21=OFF OR MS_22=OFF OR MS_12=OFF