B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 27 of 59)
ADDR
REGISTER NAME
Motor Mechanical Jam (Read/Write Grouped Setting)
69B0
Mechanical Jam Function
69B1
Mechanical Jam Pickup
69B2
Mechanical Jam Pickup Delay
69B3
Mechanical Jam Reset Delay
B
69B4
Mechanical Jam Block
69B5
Mechanical Jam Target
69B6
Mechanical Jam Events
69B7
Reserved (9 items)
Motor Learned Data (Read/Write Setting)
69D0
Motor Learned Data Starts to Learn
69D1
Motor Learned Data Calculation Period
69D2
Reserved
Motor Learned Data (Read Only Actual Values)
69D3
Motor Learned Data Records Number
69D4
Motor Learned Data Last Cleared Date
69D6
Motor Learned Data Acceleration Time
69D7
Motor Learned Data Starting Current
69D8
Motor Learned Data Thermal Capacity Used
69D9
Motor Learned Data Motor Load
69DA
Motor Learned Data Run Time After Start
69DC
Reserved
Phase Undervoltage (Read/Write Grouped Setting) (3 modules)
7000
Phase Undervoltage 1 Function
7001
Phase Undervoltage 1 Signal Source
7002
Phase Undervoltage 1 Pickup
7003
Phase Undervoltage 1 Curve
7004
Phase Undervoltage 1 Delay
7005
Phase Undervoltage 1 Minimum Voltage
7006
Phase Undervoltage 1 Block
7007
Phase Undervoltage 1 Target
7008
Phase Undervoltage 1 Events
7009
Phase Undervoltage 1 Measurement Mode
700A
Reserved (6 items)
7013
...Repeated for Phase Undervoltage 2
7020
...Repeated for Phase Undervoltage 3
Phase Overvoltage (Read/Write Grouped Setting)
7040
Phase Overvoltage 1 Function
7041
Phase Overvoltage 1 Source
7042
Phase Overvoltage 1 Pickup
7043
Phase Overvoltage 1 Delay
7044
Phase Overvoltage 1 Reset Delay
7045
Phase Overvoltage 1 Block
7046
Phase Overvoltage 1 Target
7047
Phase Overvoltage 1 Events
7048
Reserved (8 items)
Phase Directional Overcurrent (Read/Write Grouped Setting) (2 modules)
7260
Phase Directional Overcurrent 1 Function
7261
Phase Directional Overcurrent 1 Source
7262
Phase Directional Overcurrent 1 Block
7263
Phase Directional Overcurrent 1 ECA
7264
Phase Directional Overcurrent 1 Pol V Threshold
7265
Phase Directional Overcurrent 1 Block Overcurrent
7266
Phase Directional Overcurrent 1 Target
B-34
RANGE
0 to 1
1 to 10
0.1 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
---
1 to 5
1 to 90
---
0 to 250
0 to 4294967295
0 to 655.35
0 to 40
0 to 65535
0 to 40
0 to 4294967295
---
0 to 1
0 to 5
0 to 3
0 to 1
0 to 600
0 to 3
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 65535
0 to 359
0 to 3
0 to 1
0 to 2
M60 Motor Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
x FLA
0.01
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
---
F001
---
1
F001
minutes
1
F001
---
---
F001
---
1
F001
---
---
F050
s
0.01
F001
× FLA
0.01
F001
%
1
F001
× FLA
0.01
F001
hr
1
F050
---
---
F001
---
1
F102
---
1
F167
pu
0.001
F001
---
1
F111
s
0.01
F001
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F186
0 (Phase to Ground)
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
---
1
F300
---
1
F001
pu
0.001
F001
---
1
F126
---
1
F109
DEFAULT
0 (Disabled)
200
10
0
0
0 (Self-reset)
0 (Disabled)
0
1
15
0
0
0
0
0
0
0
0
0
0 (Disabled)
0 (SRC 1)
1000
0 (Definite Time)
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
0
30
700
0 (No)
0 (Self-reset)
GE Multilin