B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 25 of 59)
ADDR
REGISTER NAME
64D4
Overfrequency 1 Pickup Delay
64D5
Overfrequency 1 Reset Delay
64D6
Overfrequency 1 Target
64D7
Overfrequency 1 Events
64D8
Reserved (4 items)
B
64DC
...Repeated for Overfrequency 2
64E8
...Repeated for Overfrequency 3
64F4
...Repeated for Overfrequency 4
Motor Setup (Read/Write Setting)
6600
Thermal Model Motor FLA
6601
Thermal Model Motor Overload Factor
6602
Thermal Model Line Source
6603
Thermal Model Motor Offline
6604
Thermal Model RTD 1
6605
Thermal Model RTD 2
6606
Thermal Model RTD 3
6607
Thermal Model RTD 4
6608
Thermal Model RTD 5
6609
Thermal Model RTD 6
660A
Motor Emergency Restart
660B
Motor Nameplate Voltage
660C
Speed 2 Motor Protection
660D
Speed 2 Motor Switch
660E
Speed 2 Switch 2-1 Delay
660F
Speed 2 Motor Source
6610
Speed 2 Motor FLA
Thermal Model Actuals (Read Only)
6640
Thermal Model Motor Status
6641
Thermal Model Capacity Used
6643
Trip Time On Overload
6644
Thermal Model Lockout Time
6648
Thermal Model Load
664A
Thermal Model Motor Unbalance
664B
Thermal Model Biased Motor Load
664C
Start/Hour Lockout Time
664D
Time-Between-Starts Lockout Time
664E
Restart Delay Lockout Time
664F
Total Motor Lockout Time
Sensitive Directional Power (Read/Write Grouped Setting) (2 modules)
66A0
Sensitive Directional Power 1 Function
66A1
Sensitive Directional Power 1 Signal Source
66A2
Sensitive Directional Power 1 RCA
66A3
Sensitive Directional Power 1 Calibration
66A4
Sensitive Directional Power 1 STG1 SMIN
66A5
Sensitive Directional Power 1 STG1 Delay
66A6
Sensitive Directional Power 1 STG2 SMIN
66A7
Sensitive Directional Power 1 STG2 Delay
66A8
Sensitive Directional Power 1 Block
66A9
Sensitive Directional Power 1 Target
66AA
Sensitive Directional Power 1 Events
66AB
Reserved (5 items)
66B0
...Repeated for Sensitive Directional Power 2
Underpower (Read/Write Grouped Setting) (2 modules)
66D0
Underpower 1 Function
B-32
RANGE
0 to 65.535
0 to 65.535
0 to 2
0 to 1
0 to 1
0.05 to 1
1 to 1.5
0 to 5
0 to 65535
0 to 48
0 to 48
0 to 48
0 to 48
0 to 48
0 to 48
0 to 65535
100 to 50000
0 to 1
0 to 65535
0 to 600
0 to 5
0.05 to 1
0 to 3
0 to 100
0 to 10000
0 to 65000
0 to 40
0 to 100
0 to 40
0 to 65000
0 to 65000
0 to 65000
0 to 65000
0 to 1
0 to 5
0 to 359
0 to 0.95
-1.2 to 1.2
0 to 600
-1.2 to 1.2
0 to 600
---
0 to 2
0 to 1
0 to 65535
0 to 1
M60 Motor Protection System
APPENDIX B
UNITS
STEP
FORMAT
s
0.001
F001
s
0.001
F001
---
1
F109
---
1
F102
---
1
F001
pu
0.001
F001
---
0.01
F001
---
1
F167
---
1
F300
---
1
F151
---
1
F151
---
1
F151
---
1
F151
---
1
F151
---
1
F151
---
1
F300
V
1
F001
---
1
F102
---
1
F300
s
0.01
F001
---
1
F167
pu
0.001
F001
---
1
F098
%
1
F001
---
1
F001
min
1
F001
x FLA
0.01
F001
%
1
F001
x FLA
0.01
F001
min
1
F001
min
1
F001
s
1
F001
min
1
F001
---
1
F102
---
1
F167
degrees
1
F001
degrees
0.05
F001
pu
0.001
F002
s
0.01
F001
pu
0.001
F002
s
0.01
F001
---
---
F001
---
1
F109
---
1
F102
---
1
F001
---
1
F102
DEFAULT
500
500
0 (Self-reset)
0 (Disabled)
0
1000
100
0 (SRC 1)
0
0 (NONE)
0 (NONE)
0 (NONE)
0 (NONE)
0 (NONE)
0 (NONE)
0
600
0 (Disabled)
0
500
0 (SRC 1)
1000
1 (Starting)
0
0
0
0
0
0
0
0
0
0
0 (Disabled)
0 (SRC 1)
0
0
100
50
100
2000
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)