Ablerex RacPDU-115A User Manual

Maintenance bypass switch for on line convertible ups

Advertisement

Quick Links

User's Manual
Maintenance Bypass Switch
For On Line Convertible UPS
0

Table of Contents

Important Safety Instruction..................................................................... 2
Product Introduction................................................................................. 4
Installation and Operation ........................................................................ 5
3.1.
MTBS Unpacking..................................................................................... 5
3.1.1.
Remove the PE foam of the MTBS. .................................................... 5
3.1.2.
Check attached accessories.................................................................. 5
3.2.
Selecting Installation Position .................................................................. 5
3.3.
Maintenance Bypass Front Panel ............................................................. 5
3.4.
Installation and Operation ........................................................................ 8
Trouble Shooting .................................................................................... 14
1

Advertisement

Table of Contents
loading

Summary of Contents for Ablerex RacPDU-115A

  • Page 1: Table Of Contents

    Table of Contents Chapter 1. Important Safety Instruction..............2 Chapter 2. Product Introduction................. 4 Chapter 3. Installation and Operation ................ 5 3.1. MTBS Unpacking..................5 3.1.1. Remove the PE foam of the MTBS............. 5 3.1.2. Check attached accessories..............5 3.2.
  • Page 2: Chapter 1. Important Safety Instruction

    Do not try to repair the unit yourself, contact your local supplier or your protective warranty will be void. device • SAVE THESE INSTRUCTIONS--This manual contains important instruction RacPDU-115A RacPDU-210D 20A (cTUVus)or that should be followed while installation and operation. 16A(CB) RacPDU-120B...
  • Page 3: Chapter 2. Product Introduction

    Chapter 2. Product Introduction Chapter 3. Installation and Operation Characteristics: 3.1. MTBS Unpacking There are two operation modes offered by the Maintenance Bypass Switch: One is UPS Mode(UPS Available) and the other is Utility Mode(Maintenance 3.1.1. Remove the PE foam of the MTBS. Bypass).
  • Page 4 Figure 3: MTBS front Panel UPS Sockets:Connect to the UPS output sockets. ○ Input Socket:Connect to the Wall Receptacle. ○ CAM SWITCH:Maintenance Bypass Switch. ○ Lamps:UPS and Utility ○ &○ Load Input Sockets:Connect to the Load. ○ UPS Input Socket:Connect to the UPS Input. ○...
  • Page 5: Installation And Operation

    3.4. Installation and Operation The installation of the MTBS has three different methods. You may choose one of them in accordance with your need. For installation procedure, please refer to Figure 3. Installation Procedure: 1. Unpack the package and keep the package for future use. 2.
  • Page 6 Figure 7: Fixed Plates 2 Figure 9: Convertible Installation(2) Figure 8: Convertible Installation(1) Figure 10: Convertible Installation(3)
  • Page 7 Operation Procedure: Make sure that you may switch the modes according to the following procedure: 1. UPS MODE=>UTILITY MODE(Maintenance bypass) Step 1: Make sure the orange lamp is lit. If not, please refer to Trouble Shooting. Step 2: Switch the CAM Switch (Maintenance Bypass Switch) from UPS to Utility.
  • Page 8: Chapter 4. Trouble Shooting

    Operating Altitude: Up to 6560 ft (2000m) Orange lamp is The input power cord of *Base on RacPDU-115A not lit. the MTBS is not Connect it to the wall receptacle. ※You may choose a proper type listed below to comply with the UPS you have.