8

Supplement

8.1

Technical data

Note for approved instruments
The technical data in the respective safety instructions are valid for approved instruments (e.g. with
Ex approval). These data can differ from the data listed herein, for example regarding the process
conditions or the voltage supply.
Materials and weights
Materials, wetted parts
Ʋ Transmitter
Ʋ Diaphragm
Ʋ Joining material, diaphragm/base ele-
ment of measuring cell
Ʋ Measuring cell seal - single
Ʋ Measuring cell seal - double
Ʋ Suspension cable
Ʋ Cable gland on the transmitter
Ʋ Cable seal with PE, PUR suspension
cable
Ʋ Cable seal with FEP suspension cable FEP
Ʋ Straining clamp
Ʋ Screw connection for suspension
cable
Ʋ Threaded connection on the housing
Materials, non-wetted parts
Ʋ Housing
Ʋ Type label support on suspension
cable
Ʋ transport protection net
Materials, transmitter protection
Transport protective cap, transmitter
ø 22 mm
Transport and mounting protection, trans-
mitter ø 32 mm
Transport and mounting protection, trans-
mitter PVDF
transport protection net
VEGAWELL 52 • 4 ... 20 mA
316L, Duplex (1.4462), Duplex (1.4462) with PE coating,
PVDF, PP, Titanium
Sapphire ceramic
(99.9 % oxide ceramic)
®
Glass solder
FKM (VP2/A) - FDA and KTW approved, FFKM (Perlast
G75S), FFKM (Kalrez 6375), EPDM (A+P 75.5/KW75F)
FKM (VP2/A)+FKM (VP2/A), FFKM (Perlast
G75S)+FKM (V75J), FFKM (Kalrez 6375)+ FFKM
(Kalrez 6375), EPDM (A+P 75.5/KW75F)+EPDM (A+P
75.5/KW75F)
PE (FDA and KTW-approved), FEP, PUR
316L
FKM
316L
316L, PVDF
316L
plastic PBT (Polyester), 316L
PE hard
PE
PE
PA
PE
PE
8 Supplement