Advanced Keypad Operation Short Cuts; Drive Operating Displays - Invertek Drives ODL-2-22075-1KF42-SN Installation & Operating Instructions Manual

Optidrive elevator series ac variable speed drive for control of geared and gearless elevator motors
Table of Contents

Advertisement

28

Advanced Keypad Operation Short Cuts

Function
Fast Selection of
Parameter Groups
Note : Parameter Group
Access must be enabled
P1-14 = 101
Select lowest Group
Parameter
Set Parameter to
minimum value
Adjusting individual digits
within a parameter value

Drive Operating Displays

Display
Status

Drive mains power applied, but no Enable or Run signal applied

Motor Autotune in progress.
x.x
Drive running, display shows output frequency (Hz)
x.x
Drive running, display shows motor current (Amps)
x.x
Drive Running, display shows motor power (kW)
x.x
Drive Running, display shows customer selected units, see
parameters P2-21 and P2-22

When in rescue mode (With encoder) the direction of travel
can be displayed, it is assumed that when a run up (forward)
command (e.g. terminal 2 closed) is given the motor rotates
clockwise (looking at the motor with the sheave facing you).

Drive mains power not present, external 24 Volt control power supply present only

Output power hardware inhibited, Safe Torque Off function activated. External links are required to the STO inputs (terminals
12 and 13) as shown in section 6.8 Control Terminals Connection Diagram

Parameters reset to factory default settings

Parameters reset to User default settings (P6-29=1)
For drive fault code displays, refer to section 19.1
Managing the Keypad
Optidrive P2 Elevator User Guide V2.30
When Display shows...
xxx
xxx
xxx
Any numerical value
(Whilst editing a
parameter value)
Any numerical value
(Whilst editing a
parameter value)
www.InvertekDrives.com
Press...
The next highest
+
Parameter group is
selected
The next lowest
+
Parameter group is
selected
+
The first parameter of a
group is selected
+
The parameter is set to
the minimum value
+
Individual parameter
digits can be adjusted
Whilst the drive is running, the following displays can be
selected by briefly pressing the
Each press of the button will cycle the display through to the
next selection.
Result
Example
Display shows
Press
Display shows
Display shows
Press
Display shows
Display shows
Press
Display shows
When editing P1-01
Display shows
Press
Display shows
When editing P1-10
Display shows
Press
Display shows
Press
Display shows
Press
Display shows
Press
Display shows
button on the drive.

+


+


+

.
+
.

+


+


Etc...