Configuration Examples; Example For Configuring Single-Hop Bfd For Detecting Faults On A Layer 2 Link - Huawei AR530 Series Configuration Manual

Industrial switch routers
Hide thumbs Also See for AR530 Series:
Table of Contents

Advertisement

Huawei AR530&AR550 Series Industrial Switch Routers
Configuration Guide - Reliability

5.8 Configuration Examples

This section provides examples for the BFD configuration, including networking requirements,
configuration notes, and configuration roadmap.
5.8.1 Example for Configuring Single-hop BFD for Detecting Faults
on a Layer 2 Link
Networking Requirements
As shown in
Faults on the link between RouterA and RouterB need to be fast detected.
Figure 5-19 Single-hop BFD for detecting faults on a Layer 2 link
RouterA
Configuration Roadmap
The configuration roadmap is as follows:
Configure BFD sessions on RouterA and RouterB to detect faults on the link between RouterA
and RouterB.
Procedure
Step 1 Configure single-hop BFD on RouterA.
# Enable BFD on RouterA.
<Huawei> system-view
[Huawei] sysname RouterA
[RouterA] bfd
[RouterA-bfd] quit
# Create a BFD session on RouterA.
[RouterA] bfd atob bind peer-ip default-ip interface ethernet 2/0/0
[RouterA-bfd-session-atob] discriminator local 1
[RouterA-bfd-session-atob] discriminator remote 2
[RouterA-bfd-session-atob] commit
[RouterA-bfd-session-atob] quit
Step 2 Configure single-hop BFD on RouterB.
# Enable BFD on RouterB.
<Huawei> system-view
[Huawei] sysname RouterB
Issue 01 (2014-11-30)
Figure
5-19, RouterA and RouterB are connected through a Layer 2 interface.
Eth2/0/0
Eth2/0/0
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
RouterB