Huawei AR530&AR550 Series Industrial Switch Routers
Configuration Guide - Reliability
By default, the system checks the TTL value in VRRP6 Advertisement packets.
----End

6.7.3.5 (Optional) Enabling the Ping to a Virtual IP Address

Context
The device allows user devices to ping a virtual IP address to serve the following purposes:
l
l
If the ping to a virtual IP address is enabled, a device on an external network can ping a virtual
IP address. This exposes the device to ICMP-based attacks. The undo vrrp virtual-ip ping
enable command can be used to disable the ping function.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
vrrp virtual-ip ping enable
The ping to a virtual IP address is enabled.
By default, the ping function is enabled. The master in a VRRP group responds to ping packets
sent to the virtual IP address.
----End

6.7.3.6 Checking the Configuration

Procedure
l
l
----End
Issue 01 (2014-11-30)
Monitors the operating status of the master in a VRRP6 group.
Monitors communication between a user device and a network connected through a default
gateway that uses the virtual IP address.
NOTICE
Run the display vrrp6 [ interface interface-type interface-number ] [ vrid virtual-router-
id ] [ brief ] command to check the VRRP6 group status and parameters.
Run the display vrrp6 [ interface interface-type interface-number ] [ vrid virtual-router-
id ] statistics command to check statistics about sent and received packets of the VRRP6
group.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 VRRP Configuration
191