Download Print this page
hager 2-679-0630 Installation Instructions Manual

hager 2-679-0630 Installation Instructions Manual

Delayed egress wall controller

Advertisement

Quick Links

Verbal Exit Instructions or
Alarm Tone Only and
Digital Countdown Display
Stop Employee Theft
·
·
Stop Retail Shoplifting
Restrict Airport Patrons
·
·
Restrict Wandering Patients
The integral verbal message, digital countdown display and sign
provide comprehensive and clear instructions of the door operation
for persons without prior knowledge of the exit delay, including the
sight and hearing impaired.
The digital keypad eliminates the need to carry and locate keys for
reset and bypass functions.
Features:
Egress Delay
·
15 or 30 second exit delay
·
1 or 2 second nuisance delay
Built-In 3 Function keypad
·
Alarm and lock reset
·
1 to 30 second bypass
·
Sustained bypass
·
Additional keyswitch optional
Control Inputs
·
1 to 30 second request-to-exit and
bypass input with anti-tailgate and
jumper selectable door prop alarm.
·
Reset
Trigger Modes
·
Egress alarm triggered by Push Bar
·
Trigger input from external device
field selectable (N/O or N/C)
Code Compliance
·
IFC International fire Code
·
IBC International Building Code
·
NFPA 101 Life Safety Code
·
NFPA 1 Uniform Fire Code
·
California Building Code
·
Field selectable automatic or manual power up after emergency release or power
loss. Use of manual power up complies with California Building Code (OSHPD)
requirements.
Rev 2, Rev Date: 02/06/15
2-679-0630
WALL CONTROLLER
Built-In Annunciation
·
Armed mode
·
Nuisance mode
·
Irreversible egress mode
·
Release mode
·
Digital countdown mode
·
Field selectable voice notification or
tone
·
Field selectable male voice with
security message or female voice with
safety message
Monitoring Outputs
·
Armed mode
·
Egress initiation status
·
Released status
·
Choice of Mounting
·
Recessed mounted
(3 gang metal plaster ring included)
·
Surface mounted with optional 3
gang box (2-679-0641)
·
Optional shroud (2-679-0642) to be
used with (2-679-0641) surface box.
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995
Delayed Egress Wall Controller
Installation Instructions
Application:
When unauthorized egress is initiated 4500 DE
delays egress through the door
for 15 seconds (or 30 seconds). Meanwhile,
the person exiting must wait while personnel
or security responds. The door unlocks after
15 seconds have elapsed permitting egress.
When powered by a fire control supervised
power supply, the lock will release
immediately in an emergency.
SYSTEM SPECIFICATIONS
INPUT VOLTAGE
MAX CURRENT DRAW
(SINGLE)
(TANDEM)
MONITOR RELAYS
CONTACT RATING
TEMPERATURE
NOTE: Hager 2908 Power Supply required
I-EA00052
4500/4600
RIM MOUNT OR
VERTICAL ROD
EXIT DEVICES
INPUT VOLTAGE
430mA @ 24 VDC
680mA @ 24 VDC
1 AMP @ 12/24 VDC
(RESISTIVE)
o 0 C – 70 C
o
Page 1 of 7

Advertisement

loading

Summary of Contents for hager 2-679-0630

  • Page 1 Use of manual power up complies with California Building Code (OSHPD) requirements. Always visit www.hagerco.com for the latest Installation Instructions Page 1 of 7 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 Rev 2, Rev Date: 02/06/15...
  • Page 2 *ETW = Electric Through Wire Only ETM = Electric Through Wire w/Monitoring Always visit www.hagerco.com for the latest Installation Instructions Page 2 of 7 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 Rev 2, Rev Date: 02/06/15...
  • Page 3 PANIC DEVICE POWER SUPPLY WIRE UNIT AS SHOWN (SHOWN WITH NO OPTIONS). Always visit www.hagerco.com for the latest Installation Instructions Page 3 of 7 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 Rev 2, Rev Date: 02/06/15...
  • Page 4: Optional Features

    CONTACT THE AUTHORITY HAVING JURISDICTION FOR APPROVAL PRIOR TO SELECTING DELAY TIME OR PWR-UP SETTINGS Always visit www.hagerco.com for the latest Installation Instructions Page 4 of 7 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 Rev 2, Rev Date: 02/06/15...
  • Page 5 Remove the shorting jumper from the KP RST terminal. Always visit www.hagerco.com for the latest Installation Instructions Page 5 of 7 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 Rev 2, Rev Date: 02/06/15...
  • Page 6: Keypad Programming

    All users are erased and the Default Master Code is reset to 1234 *Multiple options may be performed without exiting programming mode. Always visit www.hagerco.com for the latest Installation Instructions Page 6 of 7 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 Rev 2, Rev Date: 02/06/15...
  • Page 7: Recommended Programming Steps

    9) Test all users and verify for desired functionallity. User User Name Name Number Code Number Code Always visit www.hagerco.com for the latest Installation Instructions Page 7 of 7 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 Rev 2, Rev Date: 02/06/15...