hager coviva Smartbox TKP100A Operation And Configuration Instructions

hager coviva Smartbox TKP100A Operation And Configuration Instructions

Hide thumbs Also See for coviva Smartbox TKP100A:

Advertisement

coviva Smartbox
hager.com
Operation and configuration instructions
coviva Smartbox
TKP100A
WLAN stick
TKH180
Power supply
(replacement requirement)
TKC110
Page 1/34
05-2019

Advertisement

Table of Contents
loading

Summary of Contents for hager coviva Smartbox TKP100A

  • Page 1 Smartbox Operation and configuration instructions coviva Smartbox TKP100A WLAN stick TKH180 Power supply (replacement requirement) TKC110 hager.com Page 1/34 05-2019...
  • Page 2: Table Of Contents

    Change settings (Figure 20) ...........................25 4 Operation..........................27 Operating concept ..............................27 Carry out a networkreset ............................30 RGB LED display ..............................31 Remote maintenance ........................31 Activate/deactivate remote access .........................32 Appendix ............................33 User profiles and rights ......................33 Further connected devices .......................34 hager.com Page 2/34 05-2019...
  • Page 3: Design And Layout Of The Device

    – coviva Smartbox – Protective cover (11) – Adapter plate for wall mounting (12) – Power supply 230 V~/5 V (13) – RJ45 connection cable, Cat 5e (14) Optional accessories – WLAN stick (15) – WLAN adapter (16) hager.com Page 3/34 05-2019...
  • Page 4: Function

    This solution is especially designed for implementing smart Home functions and comfort in mo- dernised or retrofitted systems. mobile-App Web-App Internet WLAN/IoT Mobile communications Radio (KNX radio, Twin- Band) Not available in every country. Figure 2: Application environment hager.com Page 4/34 05-2019...
  • Page 5: Correct Use

    PC, … – simple creation of scenes (covigrams) via the app – self-configurable messages after events – remote access and remote maintenance via integrated Dyn DNS service – Logic operations – Updates with notifications available online hager.com Page 5/34 05-2019...
  • Page 6: Preparations

    Fill out the personal data, agree to the use of personal data and configure „ account with Send. An e-mail with a confirmation link for activating the my Hager account will be sent to you (). Click the Complete registration button in the „...
  • Page 7: Install Coviva Mobile-App

    „ the browser. The web app opens. The web app can also be called up via the myHager account. Log into the my Hager account and select. „ Open the web app via „ The end device and smartbox must be online each time the web app is subsequently used.
  • Page 8: Project Implementation

    Enter User name and the Password for myHager account and log in with Add user. If the General Term of Use (GToU) for the coviva app have not yet been accepted in the my- Hager account, the corresponding web page must be accessed at this point. To do this, press the myHager GTC buton.
  • Page 9: Add User (Figure 7)

    Z X C V B N M Z X C V B N M Z X C V B N M .?123 .?123 space return return .?123 space return .?123 space return .?123 space return Figure 7: Create user hager.com Page 9/34 05-2019...
  • Page 10: Edit/Remove User (Figure 8)

    ID 0024C6F21834 My account Principle Date/Time 09.11.16, 00:00 Others coviva Language English Meier Installer coviva Vers. 2.6.7(cc24680) KNX Version 1.1.13 Alarm Version 1.0.6 Users My account User All users .?123 space return Figure 8: Edit/remove user hager.com Page 10/34 05-2019...
  • Page 11: Configuration Adaption

    „ The context menu for selecting the device category for the product to be integrated opens. The list of compatible products is available under hager.com/coviva. As an example, the integration of the weather station (internal module) from Netatmo is descri- bed following.
  • Page 12: Add Connected Device (Figure 10)

    Devices can be added to a group at any time. To do this, press on the group. „ The combined devices in the group are displayed. Press the blue button. „ All devices not yet added to this group are displayed. hager.com Page 12/34 05-2019...
  • Page 13: Edit/Remove Group (Figure 12)

    – Change the name of the group by activating the name line and making an entry via the keypad. – Devices to this group or remove it from this via the displayed checkboxes. – Group from the project Delete. The group is no longer displayed in the main menu. hager.com Page 13/34 05-2019...
  • Page 14 Ceiling light living Ceiling light living Wall light living r... Wall light living room Standard lamp... Standard lamp_851... my groups my groups Scene TV Scene TV Eat-in kitchen Eat-in kitchen my covigrams my covigrams Figure 12: Edit/remove group hager.com Page 14/34 05-2019...
  • Page 15: Create Covigram

    In this way, many combinations are possible. As an example, three tasks will be implemented one after another in one covigram each: hager.com Page 15/34 05-2019...
  • Page 16: Example 1: Temperature Warning (Figure 13)

    Finish the setting of the trigger with Save or discard via „ The trigger is displayed under Covigramm. Add another trigger in the same way if required, which is OR-linked, via the button, in the „ example OR-linked in the top row Heating children‘s room. hager.com Page 16/34 05-2019...
  • Page 17 Save the action and message with Save or discard via „ The triggers and action are displayed under Covigramm. Save the covigram again via Save or discard via „ The view switches to the main menu. The created covigram is displayed under my covi- grams. hager.com Page 17/34 05-2019...
  • Page 18: Example 2: Outdoor Lighting (Figure 15)

    Upon the occurrence of one of the triggers, select the switching state of the device (switched „ on/switched off) via the buttons provided - in the example Lighting entry Switched on - and finish with Save. hager.com Page 18/34 05-2019...
  • Page 19: Example 3: All Off (Figure 16)

    If … select the type of trigger, in the example „ Play The button for Trigger covigram with Play button appears. Activate button and finish with Save. „ In the detailed view of the covigram under If … is displayed. hager.com Page 19/34 05-2019...
  • Page 20 And only ... Adjust value Temperature warning Blind living room 100,0% Outdoor light 97,0 98,0 99,0 Then ... Then... All OFF 100,0 Childr. ro. Wall lig. Stand. la. Bedroom Bedroom. Study Figure 16: Covigram for example 3 hager.com Page 20/34 05-2019...
  • Page 21: Edit/Remove Covigram (Figure 17)

    With the exception of Save, finally confirm all edit operations with Delete Covigram or dis- „ card via Back. The display returns to the main menu and displays the changes. Press in the top right corner of the main menu to exit the edit mode. „ hager.com Page 21/34 05-2019...
  • Page 22 Ceiling light living Wall light living r... Wall light living room Standard lamp s... Standard lamp sofa... my groups my groups Scene Tv Scene Tv Eat-in kitchen Eat-in kitchen my covigrams my covigrams Figure 17: Edit/remove covigram hager.com Page 22/34 05-2019...
  • Page 23: Add Device To The Favourites List (Figure 18)

    The removed device is no longer displayed in the main menu under my favorites. Press in the top right corner of the main menu to exit the edit mode. „ Additional devices can be added to or removed from the favourites list in the same way. hager.com Page 23/34 05-2019...
  • Page 24 Outdoor light All OFF Groups None Alles OFF All OFF Remove from favorites my favorites Remove Device Ceiling light livin... my favorites my favorites Wall light living_... Wall light living_TR... Wall light living_... Figure 19: Remove favourites hager.com Page 24/34 05-2019...
  • Page 25: Change Settings (Figure 20)

    Select WLAN network. vated networks Enter WLAN password. The app generally uses the language set in the relevant end device. This setting only defines the language for emails and push messages. Table 2: Settings and system information hager.com Page 25/34 05-2019...
  • Page 26 Activate the Hotspot mode if want your coviva controller to open up its App Version 3.3.0 own Wifi network. Copyright Hager Group 2015 All rights reserved CHOOSE NETWORK… FRITZ-Box Figure 20: Call up/change settings hager.com...
  • Page 27: Operation

    Alternatively, you can select the desired category directly via The sequence of the categories can be changed via using drag & drop. The individual devices in the My devices category can be sorted via the favourites list (see Add device to the favourites list). hager.com Page 27/34 05-2019...
  • Page 28 Switch load on socket outlet Display of the switching state Swipe to the left/to the right Light control: Dimmer Bedroom 71% switch ON/OFF, dim LIGHTER/DAR- Set brightness of a light Display in % (0%: OFF, 100%: max. brightness) hager.com Page 28/34 05-2019...
  • Page 29 Outdoor light when activating a covigram, the stored action is not executed. The covigram must be activated before the event occurs. Touch Switch OFF all loads when leaving the All off manual triggering of a scene house. hager.com Page 29/34 05-2019...
  • Page 30: Carry Out A Networkreset

    Release RESET button (10) briefly and press once again to confirm the selection of the „ reset mode. Rapid blue flashing of the RCB LED display (1) confirms the successful reset. > 5 s Figure 21: Network reset hager.com Page 30/34 05-2019...
  • Page 31: Rgb Led Display

    Smartbox even after handing over the project, unless the admi- nistrator deliberately deactivates this. Remote access is possible either via the mobile app or via the web app (see Call up coviva web app). hager.com Page 31/34 05-2019...
  • Page 32: Activate/Deactivate Remote Access

    Vers. 2.6.7 (cc24680) Covigrams Classic Contact KNX Version 1.1.13 Favorites E-mail mike.fischer@berker.de Alarm Version 1.0.6 Phone Logout User Profile My account Principle Usernam. mike.fischer@berker.de All users Rights Installer .?123 space return Figure 22: Activate/deactivate remote maintenance hager.com Page 32/34 05-2019...
  • Page 33: Appendix

    Carry out remote maintenance  Change settings    Sort categories    Sort devices    These rights apply for the entire project process and during remote maintenance Table 6: User profiles and rights hager.com Page 33/34 05-2019...
  • Page 34: Further Connected Devices

    Applicable in all Europe and in Switzerland Hereby, hager Controls, declares that Coviva is in compliance with the essential requirements and other relevant provisions of directive 1999/5/CE (until June 2017) and directive2014/53/UE (from June 2017). The CE declaration of conformity can be consulted on the site hagergroup.com Correct Disposal of This product (Waste Electrical &...

Table of Contents