3-4 Auxiliary Output (Non-safety Output)

This device incorporates the auxiliary output for the non-safety output.
The auxiliary output is incorporated in the emitter.
Auxiliary output setting
Negative logic of OSSD
<Timing chart>
Light
Light received
received
status
Light
blocked
ON
Control output
(OSSD 1 / 2)
OFF
Auxiliary output setting
ON
Negative logic of
OFF
OSSD 1 / 2
Do not use the auxiliary output for the purpose of stopping the machine in which the SF4B-□C□
series is installed. Failure to do so could result in death or serious injury.
<Reference>
It is possible to switch the output operation for auxiliary output by using the handy controller (SFB-HC)
(optional).

3-5 External Device Monitor Function

This is the function for checking whether the external safety relay connected to the control output (OSSD
1 / 2) performs normally in accordance with the control output (OSSD 1 / 2) or not. Monitor the contacting
point "b" of the external safety relay, and if any abnormality such as deposit of the contacting point, etc. is
detected, change the status of the device into lockout one, and turn OFF the control output (OSSD 1 / 2).
● When the external device monitor function is set to be valid:
Connect the external device monitor input wire (yellow-green) to the external safety relay which is
connected to the control output 1 (OSSD 1) wire (black) and the control output 2 (OSSD 2) wire (white).
● When the external device monitor function is set to be invalid:
Connect the external device monitor input wire (yellow-green) to the auxiliary output wire
(yellow-green / black). At this time, the auxiliary output is set as [negative logic of control in
case the external device monitor input function is invalid, output (OSSD 1 / 2)] (factory set-
ting) [Set through the handy controller (SFB-HC) (optional)].
The auxiliary output cannot be connected to external devices.
<Reference>
It is also possible to set the external device monitor function into 'invalid' by using the handy con-
troller (SFB-HC) (optional).
© Panasonic Industrial Devices SUNX Co., Ltd. 2014
Ramco National
Normal operation
Control output (OSSD 1 / 2) status
Emission halt input
Light received
ON
14ms or less
20ms or less
WARNING
800-280-6933 | nsales@ramcoi.com
Light blocked
OFF
ON
90ms or less
www.panasonicsensors.com
Function
Lockout
ON
20ms or less
73