Introduction
Before the use of this device, construct the control system that satisfies the following requirements
to secure the safety of the whole system.
To use for Category 4 or 3
● To prevent the loss of the safety function due to a single fault.
Always use two types of control output (OSSD 1 / 2).
● To prevent the loss of the safety function due to the accumulation of the faults.
Construct the control system that can stop a device if discrepancy between control outputs
(OSSD 1 / 2) is detected.
<The example of the way to detect the discrepancy of control outputs>
(Example 1) Use the relay unit or the controller for the light curtain.
(Example 2) Monitor of the control outputs (OSSD 1 / 2) with the safety PLC.
(Example 3) Monitor of the contact point welding in case the safety relay is used.
To use for Category 2
If one type of control output (OSSD) is used, the auxiliary output connects to PLC to monitor the
operation of this device, and construct the control system that can stop a device if discrepancy
between the control output (OSSD) and the auxiliary output is detected. It is possible to use an-
other type of control output (OSSD) .
1-4 Confirmation of Packed Contents
□ Sensor: Emitter, Receiver
□ Test Rod
SF4B-H□C, SF4B-H□CA-J05: SF4B-TR25 (ø25 × 220mm)
□ Quick Instruction Manual (Japanese, English, Chinese, Korean)
10