Panasonic SF4B-H12C Instruction Manual page 32

Compact light curtain / type 4. sf4b series
Table of Contents

Advertisement

Mounting
Step 5 Secure bracket A, bracket B, and bracket C in place with a hexagon-socket head bolt [M3
(length: 6mm)].
The tightening torque should be 0.5N•m.
Step 6 Mount the intermediate supporting bracket for use with side mounting bracket on the
mounting surface using hexagon-socket head bolts [M5 (purchase separately)].
Note: SF4B-H□C□: 48 beam channels or more, SF4B-A□C□: 24 beam channels or more require intermediate
supporting bracket for use with side mounting bracket MS-SF4BC-7 (optional).
SF4B-H40C□, SF4B-H48C□, SF4B-H56C□, SF4B-A20C□, SF4B-A24C□, SF4B-A28C□: 1 set
SF4B-H64C□, SF4B-H72C□, SF4B-H80C□, SF4B-H88C□, SF4B-H96C□, SF4B-A32C□, SF4B-A36C□,
SF4B-A40C□, SF4B-A44C□, SF4B-A48C□: 2 sets
32
Ramco National
Hexagon-socket head bolt
[M3 (length: 6mm)]
Hexagon-socket head bolt
[M5 (purchase separately)]
800-280-6933 | nsales@ramcoi.com
Main body
Main body
© Panasonic Industrial Devices SUNX Co., Ltd. 2014
www.panasonicsensors.com