2-6 Adjustment

2-6-1 Beam-axis Alignment

Step 1 Turn ON the power supply unit of this device.
Step 2 Check that the fault indicator (yellow) of the emitter and receiver are OFF respectively.
If the fault indicator (yellow) lights up or blinks, refer to "Chapter 5 Troubleshooting,"
and report the symptoms to the maintenance in charge.
Step 3 In case of using the intermediate supporting bracket MS-SF4BC-4 or MS-SF4BC-7,
loosen the one hexagon socket head bolt [M3 (length: 6mm)].
Step 4 Loosen the four hexagon-socket head bolts [M3 (length: 6mm)] securing the mounting
bracket, and rotate the emitter and the receiver to adjust them until the beam-axis align-
ment indicators light up.
The emitter and the receiver can be fine-adjusted by ±7 degrees.
Hexagon socket head bolt
[M3 (length: 6mm)]
Utility mounting bracket (Optional)
MS-SF4BC-2 (for rear)
MS-SF4BC-3 (for side)
Side mounting bracket (Optional)
MS-SF4BC-6
© Panasonic Industrial Devices SUNX Co., Ltd. 2014
Ramco National
800-280-6933 | nsales@ramcoi.com
Adjustment
Intermediate supporting bracket for
use with utility mounting bracket
MS-SF4BC-4 (Optional)
Intermediate supporting bracket for
use with side mounting bracket
MS-SF4BC-7 (Optional)
Hexagon socket head bolt
[M3 (length: 6mm)]
www.panasonicsensors.com