Charging The Battery; Boundary Wire - Husqvarna AUTOMOWER 440 Operator's Manual

Hide thumbs Also See for AUTOMOWER 440:
Table of Contents

Advertisement

WARNING: No parts of the power supply must
under any circumstances be changed or
tampered with. The low voltage cable must not
be shortened or extended.
WARNING: Use the plug to disconnect the
charging station, for instance before cleaning
the charging station or repairing the loop wire.
CAUTION: Place the low voltage cable and
adjust the cutting height so that the blades can
never come in contact with it.
3.3.3 Installing and connecting the charging station
1. Position the charging station in a suitable spot.
2. Tilt the protective cover on the charging station
forward and connect the low voltage cable to the
charging station.
3. Connect the power supply's power cable to a
100-240V wall socket. If the power supply is
connected to an electrical socket outdoors, this must
be approved for outdoor use. See
power supply on page 13 .
4. Attach the charging station to the ground using the
supplied screws. Ensure the screws are screwed all
the way down in the countersink. If the charging
station is placed against a wall, it is best to wait
before securing the charging station to the ground
until after all the wires have been connected.
14 - Installation

3.4 Charging the battery

When the charging station is connected, it is possible to
charge the robotic lawnmower. Set the main switch to
position
Place the robotic lawnmower in the charging station
while the boundary and guide wires are being laid.
If the battery is flat, it takes around 80 to 100 minutes to
fully charge it.
Note: The robotic lawnmower cannot be used before the
installation is complete.

3.5 Boundary wire

Connecting the
The boundary wire can be installed in the following
ways:
CAUTION: It is not permitted to make new holes
in the charging station's plate. Only the existing
holes may be used to secure it to the ground.
CAUTION: Do not tread or walk on the charging
station's plate.
1 .
WARNING: Only charge the robotic lawnmower
using a charging station which is intended for it.
Incorrect use may result in electric shock,
overheating or leakage of corrosive liquid from
the battery. In the event of leakage of electrolyte
flush with water and seek medical help if it
comes in contact with the eyes etc.
Secure the wire to the ground with pegs.
Staple down the boundary wire if you want to make
adjustments to the boundary loop during the first few
weeks of operation. After a few weeks the grass will
have grown over the wire making it no longer visible.
Use a hammer/plastic mallet and pegs.
Bury the wire.
Bury the boundary wire if you want to dethatch or
aerate the lawn. If necessary, both methods can be
combined so one part of the boundary wire is
stapled down and the other is buried. The wire can
be buried for instance using an edge cutter or a
straight spade. Make sure to lay the boundary wire
at least 1 cm / 0.4 in. and a maximum of 20 cm / 8
in. in the ground.
447 - 001 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Automower 430xAutomower 420Automower 450xAutomower 440

Table of Contents