Programming Sms Messages Via Ouc - Siemens CP 1243-7 LTE Operating Instructions Manual

Simatic net
Table of Contents

Advertisement

● TMail_V4_SEC
For secure transfer of e-mails addressing the e-mail server using an IPv4 address
● TMail_QDN_SEC
For secure transfer of e-mails addressing the e-mail server using the host name
You will find the description of the SDTs with their parameters in the STEP 7 information
system under the relevant name.
You will find notes on programming SMS messages in the section Programming SMS
messages via OUC (Page 107).
Connection establishment and termination
Connections are established using the program block TCON. Note that a separate program
block TCON must be called for each connection.
A separate connection must be established for each communications partner even if
identical blocks of data are being sent.
After a successful transfer of the data, a connection can be terminated. A connection is also
terminated by calling "TDISCON".
Note
Connection abort
If an existing connection is aborted by the communications partner or due to disturbances on
the network, the connection must also be terminated by calling TDISCON. Make sure that
you take this into account in your programming.
5.2

Programming SMS messages via OUC

Transferring e-mails / SMS messages via OUC or telecontrol communication
The event-driven sending of e-mails or SMS messages using telecontrol communication is
configured in STEP 7 in the message editor, refer to the section Messages (Page 100). No
program blocks are required for this.
You only require the program blocks and system data types (SDTs) described below to
transfer SMS messages using Open User Communication (OUC).
CP 1243-7 LTE
Operating Instructions, 04/2017, C79000-G8976-C381-03
5.2 Programming SMS messages via OUC
Program blocks
107

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S7-1200 telecontrolCp 1243-7 lte-euCp 1243-7 lte-us

Table of Contents