Page 3
EMC protection at power input side, and excellent EMC protection of RJ45 port allows KIEN6000 applicable in harsh and dangerous industrial environments. The redundant function of optical fiber network, independent entire network...
Page 4
Ethernet switch; Appendix A introduces twisted pair and pin distribution rules of KIEN6000 industrial Ethernet switch; Appendix B introduces cable types and specifications of KIEN6000 industrial Ethernet switch; Appendix C introduces abbreviations used in this manful. Statement: as product and technology upgrades and improves constantly, the contents of this document may not completely accord with the actual product.
Page 5
Notice for Safety Operation This product offers reliable performances as long as it is used within the designed scope. Artificial damage or destruction of the equipment should be avoided. Carefully read this manual and well preserve this manual for future reference; ...
Page 6
Explanation of Warning Marks: This manual uses two kinds of noticeable warning signs to arouse special attention of users during operation. The implications of these signs are as follows: Warning: pay special attention to the notes behind the mark, improper operation will result in serious damage of the switch or injury of operation personnel.
Contents Chapter 1 System Overview ......................... 3 1.1 Product Overview..........................3 1.2 Features ............................... 3 1.3 Packing list and unpacking check ....................... 4 Chapter 2 Performance Indexes ........................6 2.1 System indexes ............................ 6 2.2 Service Interface ..........................7 2.3 Service function ........................... 8 Chapter 3 Hardware Structure ........................
Page 8
Chapter 6 Networking Mode and System Configuration ................ 32 6.1 Networking mode ..........................32 6.2 System configuration ......................... 35 Appendix A Twisted-pair and Pin Distribution ..................36 Appendix B Cable Type and Specifications ................... 39 Appendix C Glossary ..........................40 -ii-...
KIEN6000 industrial Ethernet switch provides two mounting ways, DIN rail and wall-mounting. On the front panel, there are two pairs of uplink redundant 100Base-FX single mode or multi-mode optical fiber interfaces.
Solid IP40 housing Easy DIN-Rail mounting or optional wall-mounting 1.3 Packing list and unpacking check 1. Packing list The packing case includes the following items: KIEN6000 1 unit 3-core DC power terminal 2 pieces 2-core alarming output terminal 1 piece...
Page 11
Before opening the case, place it stably, pay attention to the direction of the packing case, and ensure its righ t side is facing upward, so as to prevent KIEN6000 from falling apart after opening the case. If a hard object is used to unclench the case, do not overly extend the hard object into the case to avoid damage of the equipments inside the case.
Kyland Telecom Chapter 2 Performance Indexes 2.1 System indexes The system performance indexes of KIEN6000 industrial Ethernet switch are shown in Table 2-1. Table 2-1 System Indexes System Indexes KIEN6000 Quantity of RJ45 port 4 10Base-T/100Base-TX Quantity of uplink redundant 2 10Base-T/100Base-TX...
Kyland Telecom 2.3 Service function Configuration and Management At KIEN6000, the settings, queries and management can be realized for the whole switch or network system through CONSOLE interface. LED Indicator The LEDs indicate the port status correctly including transmission rate, link status and system status.
Page 15
KIEN6000 supports the broadcast storm based on percentage. With the control percentage, the broadcast flow of KIEN6000 will be monitored and controll ed effectively. The switch will filter out the over flow and ensure the flow percentage is normal once the bandwidth of broadcast flow exceed the limit.
3.2 Switch Structure 3.2.1 Case KIEN6000 case is a small DIN rail or wall mounting type structure. The entire unit has a six-side-enclosed structure, with protection class up to IP40. The case’s left and right side plates made of ribbed aluminum profile are a part of the heat dispersion system of the entire unit.
Page 17
Discarding the traditional form of axial fan heat dispersion reduces power consumption of the entire unit and increases the stability of the system. The figuration of KIEN6000 case is shown in Figure 3-2.
3.2.2 Front panel The front panel of KIEN6000 industrial Ethernet switch has integrated two pairs of uplink redundant optical fiber interfaces, six uplink redundant 10Base-T/100Base-TX Ethernet RJ45 interface (2 redundant) and six system and port operation indicators. Its...
Page 19
LED indicator The indicators on the front panel of KIEN6000 can show system operation and port status, helping detect and eliminate faults. Table 3-1 describes the meanings -13-...
Page 20
Kyland Telecom of all indication lights on the front panel. Table 3-1 LED Indicator Description Condition State System state LED The optical fiber interface of the switch is set as redundant mode and the unit is set as remote. The optical fiber interface of the switch is set as redundant 4、8RUN Blinking mode and the unit is set as remote.
Kyland Telecom 3.2.3 Top panel The top panel of KIEN6000 industrial Ethernet has integrates two power input terminals for redundant power supply, alarming relay output terminal, network management port, DIP switch for switch attribute setting etc. of t he W ar ni ng...
Page 22
Kyland Telecom 3. Insert the power terminal into the DC power socket of the equipment and a 2.5mm one-slot screwdriver to screw down the two “terminal locking screws” to firmly connect the terminal with the power connector.。 Ter m i nal Locki ng S cr ew s Locki ng S cr ew s f or P ow er C abl es P ow er G r ound...
Page 23
KYLAND Telecom in the control computer allows to realize the configuration, enquiry and management functions of all KIEN6000 equipments within the entire network The wiring sequence for network management interface of KIEN6000 and the 9-pin serial port of PC computer is shown in Figure 3-7. -17-...
Page 24
Figure 3-7 KIEN6000 network management wiring diagram DIP switch for property setting The DIP switch for setting of KIEN6000 has two positions, namely T and F. T is used for setting redundant mode and common straight-through connection mode of the two pairs of optical fiber interface. If position T shifts to ON, the two pairs of optical fiber interface are set to common straight-through connection mode, otherwise, they are set to redundant mode.
3.2.4 Bottom panel There is a threaded hole for grounding in the bottom panel of KIEN6000. M3×8 screw andФ3 cold pressed terminal for grounding free of charge will be delivered together with the main unit. As shown in Figure 3-8, crimp one end of grounding conductor to the cold pressed terminal and then use the grounding screw to fix it at the grounding hole of the shell;...
Page 26
Kyland Telecom Figure 3-8 Grounding method for KIEN6000 case -20-...
Chapter 4 Hardware Mounting 4.1 Mounting requirements KIEN6000 industrial Ethernet switch has a single body structure and can be directly mounted on standard 35 ㎜ DIN rail, or vertically mounted on the wall or inner wall of cabinet with wall-mounting components.
DIN rail. Rail mounting dimensions are shown in Figure 4-1. If it is necessary to mount KIEN6000 on DIN rail, check the mounting conditions of DIN rail before mounting, including the following two items: 1....
Kyland Telecom 2. As shown in Figure 4-2 b, clip DIN rail into the DIN rail connector socket, and ensure that KIEN6000 equipment has been reliably mounted on DIN rail. Kyland Telecom DIN Rail Model: KIEN1000-8T CAUTION! S/N: E1A8T050068 The casing is part of the heat sink design , and may be hot to the touch.
Page 30
Kyland Telecom Figure 4-3 KIEN6000 wall-mounting dimensions Attention: Wall-mounting plate is not included in standard configuration of KIEN6000. It should be ordered independently when ordering. Wall-mounting procedures for KIEN6000: 1. Use a cross screwdriver to unscrew the two screws fastening the DIN rail connector socket on KIEN6000 equipment, and remove the green DIN rail connector socket.
Page 31
Kyland Telecom W al l H angi ng Pl at e C ount er sunk Fl at head Scr ew s Figure 4-4 Mounting wall-mounting plate 3. Select mounting position: vertical wall or inner wall of cabinet. If you select to mount on vertical wall, you are recommended to use Ф6 plastic expansion bolts and Ф3 tapping screws for equipment mounting.
Kyland Telecom 4. After fastening the screws on the wall, mount KIEN6000 in the selected position. Pass the four screws through the four Ф65 holes on the wall-mounting plate and slip KIEN6000 downwards, as shown in Figure 4-5. Fasten the four screws.
4.4 Optical fiber connection KIEN6000 provides 2 pairs of redundant 100Base-FX full duplex single mode or multi-mode optical fiber interfaces. These optical fiber interfaces can be used to form an optical fiber redundant ring network. In case an equipment or optical fiber cable at some point fails, the network can recover within 300ms.
Kyland Telecom Figure 4-6 Fiber port connection 4. After accomplishing the connection, please check the LNK/ACT indicator on the front panel for the corresponding optical port. If the indicator is on, this means the connection is effective. 4.5 Cable wiring Cable wiring should meet the following requirements: 1....
Page 35
Kyland Telecom laying length of each cable should be determined according to its actual position. 4. No intermediate break or joint is allowed for the cables to be laid. 5. User’s cables and power cable should be laid separately. 6. Inside walkways, the cables should be properly arranged in good order, with uniform, smooth and flat turnings.
5.2 Testing of Ethernet interface Power KIEN6000 as shown in Fig. 5-1, make any two Ethernet interfaces connect with the network port of the two testing computers by straight-through network cable, transmit Ping command mutually, both sides can correctly Ping to each other and no data package is lost.
Kyland Telecom 5.3 Testing of optical fiber interface Let the equipment of KIEN6000 at both ends to form a fiber link network as shown in Fig. 5-2., connect any one Ethernet interface of each equipment to the testing computer by straight-through network cable, transmit Ping command mutually, both sides can correctly Ping to each other and no data package is lost.
The most typical network- forming mode of KIEN6000 is redundant ring network and redundant double ring network. KIEN6000 can form an optical fiber redundant ring network as shown in Figure 6-1, in which one end unit is set as local one, and the others as remote one.
Page 39
RO T Figure 6-1 Optical fiber redundant ring network composed by KIEN6000 KIEN6000 can form an optical fiber redundant double ring network as shown in Figure 6-2. When a fiber disconnection happens at any place, communication can be resumed within 300ms.
Page 40
Figure 6-2 Optical fiber redundant double ring network composed by KIEN6000 Attention: When KIEN6000 is forming a redundant ring network, connection of optical port 4 and 8 are recommended, namely, the optical port 4 of one end equipment shall be connected with the optical port 8 of the other end equipment.
100Base-FX100Base-FX optical fiber interfaces are with fixed configuration. The fiber port can be single-mode or multi-mode. The power supply voltage is DC 24V. The specific configuration and its corresponding models are shown as Table 6-1. Table 6-1 Configuration table of KIEN6000 Product Model Product Description...
Kyland Telecom Appendix A Twisted -pair and Pin Distribution For the connection of 10Base-T/100Base-TX, the twisted-pair must have two pair cable. Each pair is distinguished with two different colors. For example, one strand is green, and the other is the alternate of green and white stripes. RJ-45 connector should be equipped at both ends of the cable.
Page 43
Kyland Telecom hub. In straight-through cable, pin 1, 2, 3 and 6 at one end of the cable are connected to pin 1, 2, 3 and 6 at the other end of the straight-through cable respectively. Cross-over cable must be used for switch or hub with MDI-X port.
Kyland Telecom Appendix B Cable Type and Specifications The cable type and specifications are shown as table B-1: Table B-1 Cable type and specifications Cable Type Max. length Connector 100m(328 foot ) 10Base-T Cat.3, 4 and 5 100 ohm UTP RJ-45 100Base-TX Cat.5 –100 ohm UTP...
Kyland Telecom Appendix C Glossary Terminology Explanation Twisted-pair standard of Cat3, Cat4 and Cat5 in IEEE specification for 10Base-T 10Mbps Ethernet Twisted-pair standard of Cat5 or above in IEEE specification for 100Base-TX 100Mbps Fast Ethernet Fast Ethernet which uses one pair of multi-mode or single mode optical 100Base-FX fiber to transmit.
Need help?
Do you have a question about the KIEN6000 and is the answer not in the manual?
Questions and answers