  • Page 1 KIEN3016M/3024M Industrial Ethernet Switch User’s Manual KYLAND Telecom Technology Co., Ltd.
  • Page 2 KIEN3016M/3024M Industrial Ethernet Switch User’s Manual Copyright © 2006 KYLAND Telecom Technology CO., LTD. All rights reserved. No part of this documentation may be excerpted, reproduced, translated, annotated or duplicated, in any form or by any means without the prior written permission of KYLAND Corporation.
  • Page 3 EMC protection at power input side, and excellent EMC protection of RJ45 port allows KIEN3016M/3024M applicable in harsh and dangerous industrial environments. Meanwhile, it is suitable for the broadband network for building automation.
  • Page 4: Safety Notice

    Safety Notice This product offers reliable performances as long as it is used within the designed scope. Artificial damage or destruction of the equipment should be avoided.  Carefully read this manual and well preserve this manual for future reference; ...
  • Page 5 Warning Marks: This manual uses two kinds of noticeable warning signs to arouse special attention of users during operation. The implications of these signs are as follows: Warning: pay special attention to the notes behind the mark, improper operation will result in serious damage of the switch or injury of operation personnel.
  • Page 7: Table Of Contents

    Chapter Two Performance Specifications....................5 2.1 System Specifications ......................... 5 2.2 Service Interface..........................7 2.3 Service Functions ..........................7 Chapter Three KIEN3016M Hardware Structure ..................9 3.1 System Structure ..........................9 3.2 Switch Structure ..........................10 3.2.1 Chassis ............................ 10 3.2.2 Front Panel..........................
  • Page 8 6.2 Testing Ethernet Ports ........................25 6.3 Testing Fiber Ports ..........................26 Chapter Seven Networking Mode and System Configuration..............27 7.1 KIEN3016M Networking ........................27 7.2 KIEN3024M Networking ........................29 7.3 System Configurations........................30 Chapter Eight Web Management Software....................33 8.1 Software Login ..........................33 8.2 Main Page ............................33 8.3 Port Status............................34...
  • Page 9 9.1.2 Console Command........................45 9.2 Serial Port Console Interface......................46 9.2.1 Serial Port Console Main Page ....................46 9.2.2 Port Status ..........................47 9.2.3 Port Configuration ........................47 9.2.4 Trunk Configuration ....................... 48 9.2.5 VLAN Configuration ......................48 9.2.6 Port Monitoring Configuration ....................51 9.2.7 Bandwidth Control........................
  • Page 11: Chapter One Overview

    SM or MM optical fiber cables. The switches can be connected uplink via these fiber ports KIEN3016M and KIEN3024M also offer a console interface in their rear panel, by which you can manage and configure the switch via hyper terminal. You can enter into...
  • Page 12: System Features

    KIEN3016M/3024M Industrial Ethernet Switch User’s Manual 1.2 System Features High Performance Industrial Ethernet Switch Adaptive to Base-T/100Base-TX, half-duplex or full-duplex, auto MDI/MDI-X connection. Full-duplex fiber ports of 100Base-FX, single mode or multimode. Broadcasting storm protection. Conform to IEEE802.3/802.U/802.3X Transparent transmission of VLAN tag packets.
  • Page 13 Chapter One Overview 2. Unpacking check Before opening the case, place it stably, pay attention to the direction of the packing case, and ensure its righ t side is facing upward, so as to prevent switch from falling apart after opening the case. If a hard object is used to unclench the case, do not overly extend the hard object into the case to avoid damage of the equipments inside the case.
  • Page 15: Chapter Two Performance Specifications

    Chapter Two Performance Specifications 2.1 System Specifications The system specifications of KIEN3016M industrial Ethernet switch is shown as table 2-1. Table 2-1 System Specifications Specs Description 1 x RS232,RJ45 socket Management Port 16 10Base-T/100Base-TX Port Quantity & Type 0~4 x 100Base-FX-SM/MM Standard: IEEE802.3、IEEE 802.3x、IEEE 802.3u...
  • Page 16 KIEN3016M/3024M Industrial Ethernet Switch User’s Manual The system specifications of KIEN3024M industrial Ethernet switch is shown as table 2-2: Table 2-2 System Specifications Specs Description 1 x RS232,RJ45 socket Management Port 24 10Base-T/100Base-TX Port Quantity & Type 0~2 x 100Base-FX-SM/MM Standard: IEEE802.3、IEEE 802.3x、IEEE 802.3u...
  • Page 17: Service Interface

    1. KIEN3016M offers 16 RJ45 ports of 10Base-T/100Base-TX, and KIEN3024M offers 24 RJ45 ports of 10Base-T/100Base-TX. Each RJ45 port is adaptive. KIEN3016M also offers 0 to 4 fiber ports of 100Base-FX and KIEN3024M offers 0 to 2 fiber ports of 100Base-FX. The throughout of each fiber port is max 100Mbps.
  • Page 18 You can configure the service functions on the Eth-trunk port, but note to configure the OoS in the physical ports. 5. Multicasting(IGMP) IGMP means Internet Group Multicast Protocol. KIEN3016M/KIEN3024M supports IGMP surveillance and inquiry. 6. Configuring working mode of port...
  • Page 19: Chapter Three Kien3016M Hardware Structure

    Chapter Three KIEN3016M Hardware Structure 3.1 System Structure KIEN3016M hardware is structured as Figure3-1: Swi t chi ng Net w or k C ont r ol l er Power Power Port EMC protections Et her net Por t A Por t B...
  • Page 20: Switch Structure

    3.2 Switch Structure 3.2.1 Chassis KIEN3016M is a standard 19’ chassis with up to IP40 protection class. The chassis is made of aluminum with ribbed case as one part of the heat removal system. The chassis of KIEN3016M is shown in Figure 3-2: Dimensions:44 ㎜×482.6 ㎜×245 ㎜(H×W×D):...
  • Page 21: Rear Panel

    Figure 3-4 Rear Panel Fiber Port: KIEN3016M offers 4 slots for fiber ports as A,B,C,D and is custom-made for 0 to 4 fiber ports of 100Base-FX. The connector is SC. The fiber ports must be used in pair. xT is for transmitting and is connected to remote xR port. xR is for receiving and is connected to XT port.(X means A,B).
  • Page 22 KIEN3016M/3024M Industrial Ethernet Switch User’s Manual RS232, you can connect. You can use a serial cable with one end RJ45 and another end DB9F to connect the RJ232 console port with the 9-pin serial port of the PC. You can run the hyper terminal software of WINDOWS system to configure and manage the switch.
  • Page 23: Ac Power Supply

    Chapter Three KIEN3016M Hardware Structure Ter m i nal Locki ng S cr ew s Locki ng S cr ew s f or P ow er C abl es Pow er G r ound +24V P r ot ect i on G r ound Figure 3-6 DC power terminal AC power supply:...
  • Page 24 KIEN3016M/3024M Industrial Ethernet Switch User’s Manual Figure 3-7 b 2nd step -14-...
  • Page 25: Chapter Four Kien3024M Hardware Structure

    Chapter Four KIEN3024M Hardware Structure 4.1 System Structure KIEN3024M is structured in Figure 4-1: Sw i t ch Net wor k C ont r ol l er Power Pow er Por t EM C Et her net Pr ot act i on Por t A Por t B Por t 1-...
  • Page 26: Front Panel

    KIEN3016M/3024M Industrial Ethernet Switch User’s Manual Dimensions:44 ㎜×482.6 ㎜×245 ㎜(H×W×D): 482.6 CONSOLE DC POWER AC220V POWER Figure 4-2 Chassis 4.2.2 Front Panel The front panel of KIEN3024M is shown in Figure 4-3: System Running Status Port ernet 系统运行指示灯 光口指示灯 电口指示灯...
  • Page 27: Rear Panel

    Chapter Four KIEN3024M Hardware Structure Blinking active network connection fault 4.2.3 Rear Panel There are totally 2 pair of fiber ports and 24 RJ45 ports, 1 DC/AC power terminal at the rear panel shown in Figure 4-4: RS232 Control Port AC Power Switch RS232控制台端口...
  • Page 28 KIEN3016M/3024M Industrial Ethernet Switch User’s Manual You should connect the RS232 console port with the 9-pin serial port of PC as in Figure 4-5: P C机9针串口 K I E N3024M C O N S O LE 口 Figure 4-5 KIEN3024M Ethernet cable connection DC Power Supply:...
  • Page 29 Chapter Four KIEN3024M Hardware Structure connect power supply. This terminal offers a fuse socket and you can change t he fuse easily. 2A fuse is used here: 1. Plug a 2A fuse into the socket and press a standby sue into the slot for next time change as in Figure 4-7a 2.As in Figure 4-7b,plug the fuse into the AC power socket: Standby Fuse...
  • Page 31: Chapter Five Hardware Mounting

    Chapter Five Hardware Mounting 5.1 Installation Requirements KIEN3016M and KIEN3024M is a single body and can be installed in the 19’ standard rack. Before installation, make sure of the suitable environment including power requirements, installation space, close to other devices. The details are as below: 1....
  • Page 32: Cable Connection

    13 14 Figure 5-2 Mounting KIEN3016M or KIEN3024M In the Rack 5.3 Cable Connection After properly mounting KIEN3016M/KIEN3024, it is ready for cable mounting and connection, mainly including cable connection for the following interfaces: 1. Service interface KIEN3016M/KIEN3024 provides 10Base-T/100Base-TX RJ45 Ethernet interface for the connection to end equipments in straight-through way and to network equipments in cross-over way.
  • Page 33: Optical Fiber Connection

    Chapter Five Hardware Mounting 5.4 Optical fiber connection KIEN3016M/KIEN3024 provides 0~4 or 0~2 pair of ports of 100Base-FX full duplex single mode or multi-mode optical fiber interfaces. These optical fiber interfaces can be used to realize the uplink connection between switches. SC connector is required.
  • Page 34 KIEN3016M/3024M Industrial Ethernet Switch User’s Manual 3. The specifications, quantities, route directions and laying position of the cables to be laid should meet the design requirements of construction drawings. The laying length of each cable should be determined according to its actual position.
  • Page 35: Chapter Six Testing Method

    RUN indicator is on and DPX is always on.. 6.2 Testing Ethernet Ports Power KIEN3016M/3024M as shown in Fig. 6-1, make any two Ethernet interfaces connect with the network port of the two testing computers by straight-through network cable, transmit Ping command mutually, both sides can correctly Ping to each other and no data package is lost.
  • Page 36: Testing Fiber Ports

    KIEN3016M/3024M Industrial Ethernet Switch User’s Manual 6.3 Testing Fiber Ports Let the equipment of KIEN3016M.3024M at both ends to form a fiber link network as shown in Fig. 6-2., connect any one Ethernet interface of each equipment to the testing computer by straight-through network cable, transmit Ping command mutually, both sides can correctly Ping to each other and no data package is lost.
  • Page 37: Chapter Seven Networking Mode And System Configuration

    For the applications in power, transportation, energy, water and factory automation, KIEN3016M make use of the 0 to 4 pair of fiber ports to form multiple network topology flexibly and offers 16 ports of 10Base-T/100Base-TX to connect multiple...
  • Page 38 KI EN 3016 Figure 7-3 KIEN3016M Chain Topology In the broadband network in living district, KIEN3016M is suitable for the connection layer and building convergence layer. You can use the cat5 cable to connect the 10/100M broadband and one pair fiber port of 100Base-FX to uplink to the...
  • Page 39: Kien3024M Networking

    Chapter Seven Netwo rking Mode and System Configuration 7.2 KIEN3024M Networking KIEN3024M offers 0 to 2 pair of fiber ports of 100Base-FX to be connected to KIEN2000B, KOM300, KIEN3016 to form a large, chain, tree topology network. It can be widely used in power, transportation, energy and water, factory automation etc, also to form broadband network in building.
  • Page 40: System Configurations

    Figure 7-6 KIEN3024M Broadband Network 7.3 System Configurations KIEN3016M and KIEN3024M are integrated structures offering 16 or 24 Ethernet ports of 10Base-T/100Base-TX which are fixed. Additionally, they offer 4 or 2 fiber modules of 100Base-FX. The power supply can custom-made as AC220V、DC220V、...
  • Page 41 Chapter Seven Netwo rking Mode and System Configuration Table 6-1 KIEN3016M、KIEN3024M Configuraations Model Description KIEN3016M 4 x 100Base-FX, SM, KIEN3016M-4S 16 x 10Base-T/100Base-TX, RJ-45 3 x 100Base-FX, SM, KIEN3016M-3S 16 x 10Base-T/100Base-TX, RJ-45 2 x 100Base-FX, SM, KIEN3016M-2S 16 x 10Base-T/100Base-TX, RJ-45 1 x 100Base-FX, SM,...
  • Page 43: Chapter Eight Web Management Software

    Chapter Eight Web Management Software 8.1 Software Login You can configure and manage via console or web software. This chapter will cover all details of the web management software. The serial port management will be introduced in next chapter. Open IE browser and enter IP address, press “ENTER” to login with user name of “admin”, password of “admin”, click “advanced setting”.
  • Page 44: Port Status

    KIEN3016M/3024M Industrial Ethernet Switch User’s Manual Figure 8-2 WEB Main Page 8.3 Port Status Click Port status to show the status of each port:enable、up/down、100F/10T、traffic control ON/OFF. Figure 8-3 Port Status Page 8.4 Port Configuration Click Port configuration to enter into the page port configuration to show the parameters: enable/disable、...
  • Page 45: Trunk Configuration

    Figure 8-4 Port Configuration 8.5 Trunk Configuration Click Trunk configuration to enter into the page of trunk. For KIEN3016M, up to 7 TRUNK is possible. You can bind 2 to 8 ports for each trunk. MOD1 and MOD2 must be binding together without other ports.
  • Page 46: Port-Based Vlan Configuration

    KIEN3016M/3024M Industrial Ethernet Switch User’s Manual Figure 8-6 VLAN Configuration 8.6.1 Port-based VLAN Configuration Add VLAN ID number in the volume of GROUP ID in the range of 1 to 4094. Select the port. For example, port 1, 4 is member state and click APPLY key. VLAN is configured successfully.
  • Page 47: Port Monitoring Configuration

    Chapter Ei ght Web Management Software Figure 8-8 802.1qQ-based VLAN Configuration a Click “ Advanced 802.1Q VLAN Setting” , to enter into Advanced 802.1Q VLAN Setting interface,set the port as nonmeber(drop/forward)、untag(drop/forward). Figure 8-9 802.1qQ-based VLAN Configuration b 8.7 Port Monitoring Configuration Click ”Port Monitoring Configuration”...
  • Page 48: Port Rate Configuration

    KIEN3016M/3024M Industrial Ethernet Switch User’s Manual Figure 8-10 Port Monitoring Configuration Select mirrored and mirroring port and click APPLY to finish configurations: Figure 8-11 Select Port 8.8 Port Rate Configuration Click “ Bandwidth Control” to enter into Bandwidth Control page and configure the rate of each port with each unit of 1MBIT.
  • Page 49: Qos

    Chapter Ei ght Web Management Software Figure 8-12 Port Rate Configuration 8.9 QOS Click the left menu:“ QOS Configuration” to enter into QOS page: Select QOS mode:Disable / High Empty Then Low / weight8:4:2:1 / 15:7:3:1 / 15:10:5:1 QOS default mode :Weight 8:4:2:1 Options for each port:0~7 802.1p priority mode:...
  • Page 50: Acl

    KIEN3016M/3024M Industrial Ethernet Switch User’s Manual 8.10 ACL Click left menu “ ACCESS control list” to enter “ ACCESS control list” page, access control list includes:Ipv4 ACL Configuration、Non-Ipv4 ACL Configuration. For the two configurations,Group ID(1~246) 、action(permit/deny)、VLAN are all applicable. Click APPLY to finish.
  • Page 51: Non-Ipv4 Acl Configuration

    Chapter Ei ght Web Management Software *** is range from 0 to 255. 255.255.255.25 ***.***.***.*** * is represent a digit from 0~9, Src IP NetMask ** is range from 0 to 255. Notice: This is not subnet mask. Any / Specify a.
  • Page 52: Other Configurations

    KIEN3016M/3024M Industrial Ethernet Switch User’s Manual 8.11 Other Configurations Click left“ Msic Operation” to enter into other configuration page. 8.11.1 Advanced Configuration Click “ Advanced switch configuration”, to configure “ Broadcast storm” , and set the bandwidth of the broadcasting data as “1/2、1/4、1/8、1/16、OFF” .
  • Page 53: Igmp-Snooping Enable

    Chapter Ei ght Web Management Software 8.11.3 IGMP-snooping Enable Click“ IGMP configuration”, to enter IGMP-Snooping starting page and select Disable/enable. Click APPLY to finish. Figure 8-17 IGMP Configuration 8.11.4 IP Address Configuration Click“ IP Configuration” to enter page and change the IP address, gateway, subnet etc and click APPLY to finish.
  • Page 54: Update Configuration

    KIEN3016M/3024M Industrial Ethernet Switch User’s Manual 8.11.5 Update Configuration Click“ Firmware Update” to enter into update page and key into IP address and software name, click APPLY to finish. Figure 8-19 Update -44-...
  • Page 55: Chapter Nine Console Management

    Chapter Nine Console Management 9.1 Functional Key and Command 9.1.1 Functional Key Table 9-1 Description Move the cursor to right item. TAB/ Move the cursor to left item. Backspace/ Move the cursor to up item. Move the cursor to down item. Toggle selected item to next configuration.
  • Page 56: Serial Port Console Interface

    9.2.1 Serial Port Console Main Page Enter into hyper terminal and configure the parameters of port, connect PC with KIEN3016M or KIEN3024M,click“ ENTER” ,to enter the main page: enter into username of admin and password of admin, click “ENTER” to the main menu: shown...
  • Page 57: Port Status

    Chapter Nine Console Management 9.2.2 Port Status In Figure 9-2, select “ Port Status” to show status,as figure 9-3, “ Quit” to return to last menu: Figure 9-3 Port Status 9.2.3 Port Configuration In figure 9-2, select“ Port Configuration” to enter into page, as in figure 9-4,select “...
  • Page 58: Trunk Configuration

    KIEN3016M/3024M Industrial Ethernet Switch User’s Manual 9.2.4 Trunk Configuration Trunk In figure 9-2 select “ Configuration” to enter into TRUNK page and as shown in figure 9-5, select “Edit” to edit the trunk state. For example, change disable to enable for TRUNK1, move and select port, when the state of port is changed from “...
  • Page 59 Chapter Nine Console Management Figure 9-6 VLAN configuration Select “ Edit” and click “ enter” 。 VLAN Mode: Portbased。Select “ ADD” click “ enter” to add VLAN,enter “ ADD Portbased VLAN Group” as shown in Figure 9-8,select Group ID(ID=1~4094),Select port(port1~port24、mod1~mod2 any) 。 Save the configuration.
  • Page 60 KIEN3016M/3024M Industrial Ethernet Switch User’s Manual Figure 9-8 Port Configuration 9.2.5.2 IEEE 802.1Q (tag) -based In Figure 9-9, select “ Edit” and click “ enter” 。 VLAN Mode: 802.1q。 Select “ ADD” and click“ enter” to add VLAN,enter“ ADD A 802.1Q VLAN Group” As shown in Figure 9-10,select Group ID(ID=2~4094), select port (port1~port24、...
  • Page 61: Port Monitoring Configuration

    Chapter Nine Console Management Figure 9-10 Figure 9-11 In this page, configure the two status of port:。 “ nonmember” ,default at “ drop” drop the tagged packet but not fromVID. “ forward” means forward. “ Untagged” , default at “ forward” , to forward the untagged packets. “ drop” means drop.
  • Page 62: Bandwidth Control

    KIEN3016M/3024M Industrial Ethernet Switch User’s Manual Figure 9-12 Figure 9-13 Bandwidth Control 9.2.7 In figure 9-2, select“ Bandwidth Cotrol” and click “ enter ” to enter into “ Bandwidth Cotrol” page, as shown in figure 9-14, select the inrate and outrate and save.
  • Page 63: Qos Configuration

    Chapter Nine Console Management Figure 9-14 Bandwidth Cotrol QoS Configuration 9.2.8 In figure 9-2, select“ Qos Configuration” , and click “ enter” to enter into“ Qos Configuration” page, as shown in figure 9-15,select QOS Mode: Disable / High Empty Then Low / weight=8:4:2:1 / 15:7:3:1 / 15:10:5:1; default at weight=8:4:2:1。 The data are queued in two ways: 802.1p-based and port-based.
  • Page 64: Access Control List

    KIEN3016M/3024M Industrial Ethernet Switch User’s Manual Figure 9-16 Port Counter Access Control List 9.2.10 In figure 9-2, select “ Acess ACL Configuration” , click “ enter” to enter “ Acess ACL Configuration” page, as shown in figure 9-17. Figure 9-17 Acess ACL Configuration 9.2.10.1 Ipv4 ACL Configuration...
  • Page 65 Chapter Nine Console Management Figure 9-18 9.2.10.2 Ipv4 ACL Group <Add> / <List> Menu In Figure 9-20, select the parameters of table9-3. Table 9-3 Items Option Default value Group ID 1 ~ 255 (max. 255 ACL group) Permit Action Permit / Deny. Permit: Permit packet cross switch.
  • Page 66 KIEN3016M/3024M Industrial Ethernet Switch User’s Manual * is represent a digit from 0~9, *** is range from 0 to 255. Dst IP 255.255.255.25 ***.***.***.*** NetMask * is represent a digit from 0~9, *** is range from 0 to 255. L4 Protocol...
  • Page 67 Chapter Nine Console Management 9.2.10.3 Non-Ipv4 ACL Configuration In figure 9-17, select“ Non-Ipv4 ACL Configuration” , enter into“ Non-Ipv4 ACL Configuration” page,as shown in figure 9-21 Figure 9-21 9.2.10.4 Non-Ipv4 ACL Group <Add> / <List> Menu In figure 9-21 select “ Delete” to delete ACL GROUP list. Select “ ADD” to enter into Figure 9-22。...
  • Page 68: Misc Operation

    KIEN3016M/3024M Industrial Ethernet Switch User’s Manual Figure 9-22 9.2.11 Misc Operation , click “ enter” In figure 9-2, select“ Misc Operation” to enter“ Misc Operation” page as shown in figure 9-23. Figure 9-23. 9.2.11.1 Advanced Switch Configuration , click “ enter”...
  • Page 69 Chapter Nine Console Management Items Option Default value Broadcast Storm Filter Off / 1/2 / 1/4 / 1/8 / 1/16 of ingress rate Collision Retry Forever Disable / Enable Enable MAC Table Auto-Aging Disable / 150 / 300 / 600 seconds 300 seconds MAC Table Hashing CRC Hash / Direct Map...
  • Page 70 KIEN3016M/3024M Industrial Ethernet Switch User’s Manual Figure 9-25, 9.2.11.3 Multicast Filtering (IGMP) In figure 9-23, select “ Multicast Filtering(IGMP)” , click “ enter” to enter “ Multicast Filtering(IGMP)” page as shown in Figure 9-26 to enable IGMP according to Table 9-7:...
  • Page 71 Chapter Nine Console Management 9.2.11.4 IP Configuration In figure 9-23, select “ IP Configuration” to enter into “ IP , click“ enter” Configuration” page as shown in Figure 9-27 to configure according to table 9-8: Table 9-8 Items Option Default Value IP Address ***.***.***.***...
  • Page 73: Appendix A Twisted-Pair And Pin Distribution

    Appendix A Twisted -pair and Pin Distribution For the 10Base-T/100Base-TX, the twisted-pair should present two pair of wires. Each pair is differentiated by different colors. For instance, the one is green and the other is the green and white interleaved. There should be the RJ-45 connector at both sides of cables.
  • Page 74 KIEN3016M/3024M Industrial Ethernet Switch User’s Manual hubs. In the direct connection wire, pin 1, 2, 3 and 6 are at the same end of the cable and are connected to the pin 1, 2, 3 and 6 at the other end of the connection cable.
  • Page 75 第六章 本章名称 -65-...
  • Page 77: Appendix B Cable Type And Specifications

    Appendix B Cable Type and Specifications The cable type and specifications are shown as table B-1: Table B-1 Cable type and specifications Cable Type Max. length Connector 100m(328 foot ) 10Base-T Cat.3, 4 and 5 100 ohm UTP RJ-45 100m(328 foot ) 100Base-TX Cat.5 –100 ohm UTP RJ-45...
  • Page 78: Appendix C Glossary

    Appendix C Glossary Terminology Explanation Twisted-pair standard of Cat3, Cat4 and Cat5 in IEEE specification f or 10Base-T 10Mbps Ethernet Twisted-pair standard of Cat5 or above in IEEE specification for 100Base-TX 100Mbps Fast Ethernet Fast Ethernet which uses one pair of multi-mode or single mode optical 100Base-FX fiber to transmit.