Server Set Command - Equinox Systems Equinox Console Manager CCM4850 CCM4850 CCM4850 Installer/User Manual

Network device avocent hardware manual
Table of Contents

Advertisement

54
CCM4850 Installer/User Guide
Syntax
SERVER SECURITY [AUTHENTICATION=<auth>] [ENCRYPT=<conns>]
[LOCKOUT=<hours>]
Table 5.14: Server Security Command Parameters
Parameter
AUTHENTICATION=
<auth>
ENCRYPT=<conns>
LOCKOUT=<hours>

Server Set command

The Server Set command changes CCM appliance address settings. You may specify one, two or
all three parameters. A reboot is required if you change the IP address.
Access right: SCON
Access level: APPLIANCEADMIN
Syntax
SERVER SET [IP=<ip_address>]
Table 5.15: Server Set Command Parameters
Parameter
IP=<ip_address>
MASK=<subnet>
GATEWAY=<gtwy>
Description
Authentication method. You may specify multiple values (other than None),
separated by commas. Valid values are:
LOCAL
Use the local CCM user database to authenticate users.
RADIUS Use the previously defined RADIUS server(s) to authenticate users.
NONE
Do not authenticate users. This method cannot be used when SSH access
is enabled, and it cannot be combined with other authentication methods.
Default = LOCAL
Enables/disables plain text Telnet or SSH connections. You may enable both by
specifying both values, separated by a comma. Valid values are:
SSH
Enables SSH connections.
None
Enables plain text Telnet connections.
Default = None
Enables or disables security lock-out. To enable, specify the number of hours in the
lock-out period, in the range 1-99. To disable, specify a zero value.
Default = 0 (disabled)
[MASK=<subnet>]
Description
IP address.
Subnet mask for the subnet on which the CCM appliance resides.
IP address of default gateway for routing IP packets.
[GATEWAY=<gtwy>]