Photon Focus MV1-D1280-L01-1280-G2-12 User Manual page 59

Mv1-d1280-l01 camera series cmos camera with gige interface
Table of Contents

Advertisement

A/B Trigger Divider
if ABTriggerDivider>1 then not all internally generated triggers are applied to the camera logic.
E.g. If ABTriggerDivider=2, then every second trigger is applied to the camera (see Fig. 5.23).
)
B
G r a y C o u n t e r
0
E n c o d e r C o u n t e r
0
I n t e r n a l T r i g g e r F w d
A p p l i e d T r i g g e r F w d
Figure 5.23: A/B Trigger Divider, example with ABTriggerDivider=1, ABMode=quad
A Only Trigger
The camera supports the use of simple incremental decoders that only provide one input, by
enabling the property ABTriggerAOnly. The B-signal is ignored in this mode and information
about direction of the object movement is not available: if ABTriggerAOnly is enabled then the
encoder position is always incremented. Detailed diagrams are shown in Fig. 5.24 and Fig.
5.25. Note that the quad mode is not available when ABTriggerAOnly=true.
)
E n c o d e r C o u n t e r
0
T r i g g e r F w d
T r i g g e r B k w d
T r i g g e r F w d B k w d
Figure 5.24: AOnly Trigger in Single A/B Mode
)
E n c o d e r C o u n t e r
0
T r i g g e r F w d
T r i g g e r B k w d
T r i g g e r F w d B k w d
Figure 5.25: AOnly Trigger in Double A/B Mode
Encoder Position
The internal ABTrigger signal before the ABTriggerDivider is processed for the Encoder
Position: every TriggerFwd pulse increments the Encoder Position and every TriggerBkwd pulse
decrements its value. For details refer to the diagram of the corresponding mode.
The Encoder Position value can be accessed through the EncoderPosition property or through
the status info that is inserted into the image (see Section 5.10).
MAN077 11/2017 V1.0
1
2
3
0
1
2
1
2
3
4
5
6
1
2
1
2
3
3
2
1
0
3
7
6
5
4
3
3
4
5
6
5.2 Trigger and Strobe
2
1
2
3
0
2
1
2
3
4
4
5
7
8
9
59 of 139
1
5
1 0

Advertisement

Table of Contents
loading