PROGRAMMING:
Use the dip switch method of programming shown below when installing the GT-1C7(-L), GT-1M3(-L), or GT-2C(-L).
When installing the GT-1A or GT-1D, use the handshake method shown on pages 14-15 after uploading tenant,
entrance, and guard information to the stations. If using a mix of stations that allow for dip switch settings
(GT-1C7(-L), GT-1M3(-L), and GT-2C(-L)) and stations that do not (GT-1A, GT-1D), it is recommended to program all
stations using the handshake method.
Step 1:
Create an ID correlation table for the tenant stations using a binary / SW2 Dip Switch - ID chart.
The chart below is for up to 48 stations in a non-expanded system.
The full Dip Switch chart can be downloaded from
Dip Switch
S10
S11
S12
Step 2:
Set the SW2 dip switches found on the back of the GT-1C7(-L), GT-1M3(-L), and GT-2C(-L) according to
the correlation table created in the previous step.
GT-1C7(-L)
GT-1M3(-L)
Step 3:
Enter the ID from the correlation table in Step 1 into the Unit Link-ID Setting for each station.
Step 4:
Click Save
8 | GT Series Quick Start Guide
ADDRESSING TENANTS VIA DIP SWITCH METHOD
ID
Dip Switch
S1
S2
S3
S4
S5
S6
S7
S8
S9
GT-2C(-L)
, and then Yes .
http://www.aiphone.net/product/support/gt/
ID
Dip Switch
S13
S14
S15
S16
S17
S18
S19
S20
S21
S22
S23
S24
SW2
On
Off
128 64 32 16 8 4 2 1
GT-1A or GT-1D: Leave blank.
Program via handshake method.
Pages 14-15.
ID
Dip Switch
S25
S26
S27
S28
S29
S30
S31
S32
S33
S34
S35
S36
ID
S37
S38
S39
S40
S41
S42
S43
S44
S45
S46
S47
S48