Settings and Adjustments

Station Programming

Connect to the same network as the Door Station and manage the settings from PC web browser. If the Expanded
System setting has been set to "Enable" in the Admin Settings, the setting cannot be set using a PC.
System requirements
The programming PC must meet the following requirements to proceed.
Network
Web browser
Connecting to a PC
Using a Cat5e/6 "Straight-Through" cable, connect the station and PC to the same PoE switch or injector.
Door Station
Login to this station
1.
Start the PC and open one of the before mentioned web browsers.
2.
Enter the address below into the web browser address bar.
• IPv4 example - https://IP address of this device/webset.cgi?login
• IPv6 example - https://[IP address of this device]/webset.cgi?login
• If a certificate error window is displayed, click [Go on to the webpage]. To prevent it from appearing, the
administrator will need to disable it. Contact your system administrator.
• Language selection window will be displayed.
Ethernet (10BASE-T, 100BASE-TX)
Microsoft Edge / Internet Explorer 10.0, 11.0 / Mozilla Firefox 59 or 60 (TLS1.0, 1.1, or 1.2
enabled)
RJ45
RJ45
CAT5e/6 straight cable
Station programming
RJ45
PoE
CAT5e/6 straight cable
compatible
switch
41
RJ45
PC