Gigabyte Boundary - Promise Technology UltraTrak100 TX4 User Manual

Promise technology ultratrak100 tx4 and ultratrak100 tx8 user manual
Hide thumbs Also See for UltraTrak100 TX4:
Table of Contents

Advertisement

If you wish to make a RAID 0+1 array using 4, 6, or 8 drives you need to
choose RAID 1 (mirroring) and then follow the steps below to create the
array.
9.
Press SEL to assign Stripe Block Size. 64KB is the optimum value for most
applications. Choosing the proper Stripe Block Size facilitates efficient data
flow. You might want to choose a different value if you know the size of the
cache buffer in your hard drives or the average data block size of the data
you retrieve. See Choosing Stripe Block Size on page 10 for more
information.
10. Press
button to choose the GB Boundary feature. Press SEL to toggle
between GB Boundary ON and GB Boundary OFF. The size of the array is
always restricted by the size of the lowest capacity disk drive. GB Boundary
ON (recommended) causes the size of the array to be rounded down to the
nearest whole gigabyte. GB Boundary OFF does not round off the size of
the array. (For example: Enabled—1.6GB = 1GB; Disabled—1.6GB =
1.6GB.) See Gigabyte Boundary below for more information.
The Gigabyte Boundary feature is only available for RAID levels 1, 0+1,
3, and 5.
11. Press
button to choose the Add/Remove Drives feature then press SEL.
12. Use the
and
adding or removing a drive. Press EXIT when done.
13. Press SEL to Save Changes
14. Press SEL to create the array or press EXIT to cancel.
15. If you pressed SEL to create the array then you should see the message
"Array has been created."
16. Switch the UltraTrak100 power off – wait 5 seconds and switch the power
back on.
You have successfully created an array manually. If haven't already done so, you
need to select a SCSI ID before you can begin using the UltraTrak100.
G
B
IGABYTE
OUNDARY
The Gigabyte Boundary feature is designed for fault tolerant arrays (RAID 1, 0+1,
3 and 5) in which a drive has failed and the user cannot replace the drive with the
same capacity or larger. Instead, the Gigabyte Boundary feature permits the
installation of a replacement drive that is slightly smaller (within 1 gigabyte) than
the remaining working drive (for example, a 20.5 GB drive would be rounded down
to 20 GB). This can be helpful in the event that a drive fails and an exact
replacement model is no longer available. Without this feature enabled,
UltraTrak100 will NOT permit the use of a replacement drive that is slightly smaller
than the remaining working drive.
button to select each drive. Press SEL to toggle between
Note
Note
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultratrak100 tx8

Table of Contents