Aaeon AMB-2427 Series Manual

12.1/15” tft flat-panel industrial workstation

Advertisement

Quick Links

I n d u s t r i a l W o r k s t a t i o n
A M B - 2 4 X X
AMB-2427/2457/
2450 Series
12.1/15" TFT Flat-panel
Industrial Workstation
1
AMB -24xx series User Manual V1.2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMB-2427 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aaeon AMB-2427 Series

  • Page 1 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X AMB-2427/2457/ 2450 Series 12.1/15” TFT Flat-panel Industrial Workstation AMB -24xx series User Manual V1.2...
  • Page 2: Packing List

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Packing List Before you set up the AMB-24xx Serial workstation, make sure that the following items have been included in your package, and that this manual is in good condition.
  • Page 3: Safety & Warranty

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Safety & Warranty Read these safety instructions carefully. Keep this user's manual for later reference. Disconnect this equipment from any AC outlet before cleaning.
  • Page 4: Fcc Safety

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X BELOW -20° C (-4° F) OR ABOVE 60° C (140° F). IT MAY DAMAGE THE EQUIPMENT.
  • Page 5 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Contents Packing List ................2 Safety & Warranty..............3 FCC Safety................4 General Information ..........
  • Page 6: General Information

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Chapter General Information AMB -24xx series User Manual V1.2...
  • Page 7: Introduction

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Introduction Astech designed the AMB-2427/2457/2450 specifically for the factory floor and other harsh industrial environments.
  • Page 8 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X on the front panel. Finger Mouse Finger mouse is a standard function at AMB-24xx series. It’ s a standard PC compatible mouse and make this workstation have full function assist you to control everything with this workstation.
  • Page 9 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X power indicators for +5 V, +12 V, -5 V and -12 V. AMB -24xx series User Manual V1.2...
  • Page 10: Specifications

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Specifications General • Construction: Painted metal steel chassis & aluminum alloy •...
  • Page 11: Lcd Display

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X LCD display Model AMB-2457/2450 AMB-2427 Display type TFT color LCD TFT color LCD Size (diagonal) 15”...
  • Page 12: Front Panel

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Front panel Keypads: One with 59 operating keys, one with 24 function keys Keyboard connector: PS/2 connector with dust-protection cover on front panel If you would like to connect external keyboard or mouse, please notice:...
  • Page 13: Environmental Specifications

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Output voltage: +5 V @ 25 A; +12 V @ 10 A; -5 V @ 1 A; -12 V @ 1 A MTBF: >150000Hrs per MIL –...
  • Page 14: Basic Operations

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Basic Operations All the operations of your works can be down from panel. You can enter any kind of data by using the two sealed membrane keypads: one with 59 data keys and the other with 24 function keys or connect external keyboard for fast data key in.
  • Page 15 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X 2. Open front Panel function 3. Front Panel real side AMB -24xx series User Manual V1.2...
  • Page 16: Dimension

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Dimension AMB-2427series 24.5 AMB-2427 A L T A L T PgUp PgUp &...
  • Page 17 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X AMB-2450series 435.2 23.3 409.2 AMB-2450 PgUp PgDn CTRL SHIFT & < >...
  • Page 18: Rack Mounting

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Rack Mounting The AMB-24xx series can be mounted in a 19" rack. Ensure that all additional equipment has been installed correctly and that the cabling has been reattached.
  • Page 19: Hardware Installation

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Chapter Hardware Installation AMB -24xx series User Manual V1.2...
  • Page 20: Exploded Diagram

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Exploded Diagram The diagram shows all the components and parts that make up the AMB-24xx series.
  • Page 21 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X AMB-2457series AMB-2450series AMB -24xx series User Manual V1.2...
  • Page 22: Passive Back Plane

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Passive Back plane As we said in section 1.2 the workstation each come with an ISA/PCI bus 7 and 10 slots passive backplane.
  • Page 23 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X 10 slots passive back plane AMB -24xx series User Manual V1.2...
  • Page 24: Install Cd-Rom , Hard Disk Drives And Floppy Disk Drive

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Install CD-ROM , Hard Disk Drives and Floppy Disk Drive Every disk drive bay has a disk driver holder, which fastened to its bay with screw on the both sides.
  • Page 25 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Install HDD Cable Install FDD Cable AMB -24xx series User Manual V1.2...
  • Page 26 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Install CD-ROM Cable Install in Chassis AMB -24xx series User Manual V1.2...
  • Page 27 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Fasten in chassis with two screws AMB -24xx series User Manual V1.2...
  • Page 28: Power Supply Replacement

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Power Supply Replacement A universal 250W switching power supply is provided in the Workstation (for other options please refer to Appendix B).
  • Page 29: Cooling Fan Replacement

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Cooling Fan replacement A 64 CFM fan is installed with in a housing to keep the working temperature inside of the chassis.
  • Page 30 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X 3. Install / replace fan filter AMB -24xx series User Manual V1.2...
  • Page 31: Cpu Card Installation

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X CPU Card Installation Signal transfer between CPU card and front panel via a transfer board. The signal include Keyboard, mouse, VGA and touchscreen.
  • Page 32 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X From TB-908D to CPU card (1) From TB-908D to CPU card (2) AMB -24xx series User Manual V1.2...
  • Page 33 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X From TB-908D to CPU card (3) AMB -24xx series User Manual V1.2...
  • Page 34: Vga Jumper Setting

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X VGA Jumper setting 15” LCD Panel Jumper setting on DV69K 12.1” LCD Panel Jumper setting on DV69K AMB -24xx series User Manual V1.2...
  • Page 35: Power Supply Specification

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Appendix Power Supply Specification AMB -24xx series User Manual V1.2...
  • Page 36: Power Supply Specification

    I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Power Supply Specification Power supply constitutes an essential part of the panel PCs, so we make this section to let you know more about the power supply used in them.
  • Page 37 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Output # +5V: +/-3% +12V: +/-5% -5V: +/-1% -12V: +/-1% Hold-up Time: Hold-up Time is 16ms typical by measuring from the last AC line changing pulse to the point that +5V drop down to +4.75V Output Protection: The built-in over voltage protection circuit will shut down the outputs to prevent damaging external circuits.
  • Page 38 I n d u s t r i a l W o r k s t a t i o n A M B - 2 4 X X Selection Table Input/Output spec. at 40℃ Max. Output Current Model Input voltage +12V -12V Universal 250W...

This manual is also suitable for:

Amb-2450 seriesAmb-2457 series

Table of Contents