Run Signal [Run] - Hyundai N700E Instruction Manual

Hide thumbs Also See for N700E:
Table of Contents

Advertisement

N700E INSTRUCTION MANUAL

Run Signal [RUN]

When the [RUN] signal is selected as an intelligent output terminal, the inverter outputs a signal on that
terminal when it is in the Run Mode.
The output logic is active low, and is the open collector type (switch to ground)
Option
Terminal
Code
Symbol
0
RUN
Valid for inputs:
Required setting
Notes:
• The inverter outputs the [RUN] signal whenever
the inverter output exceeds the start frequency.
The start frequency is the initial inverter output
frequency when it turns on.
The example circuit in the table above drives a relay coil. Note the use of a diode to prevent
the negative-going turn-off spike generated by the coil from damaging the inverter's output transistor.
Input
Function Name
State
ON
Run signal
OFF
C13
0
when inverter is in Run Mode
when inverter Stop Mode
5-17
Description