Basic Function Mode - Hyundai N700E Instruction Manual

Hide thumbs Also See for N700E:
Table of Contents

Advertisement

N700E INSTRUCTION MANUAL
4.2.3

Basic Function Mode

Func-
Name
code
F01
Output frequency setting
Acceleration time1
F02
setting
Deceleration time 1
F03
setting
F04
Rotation direction setting
Extended function of
A--
A group setting
Extended function of
b--
b group setting
Extended function of
C--
C group setting
Extended function of
H--
H group setting
Note) If you set the carrier frequency less than 2kHz, acceleration / deceleration time delays approximately
500msec.
Description
Standard default target frequency that
determines constant motor that deter-mines
constant motor speed. setting range
is 0.00 to 400.0Hz
(1) frequency setting from UP/DOWN key of
digital operator.
(2) Multi-step speed
By combining frequency reference
and intelligent input terminal ON/
OFF, up to 16 step of speed can be set.
(3) Remote operator (NOP), control
terminal input (O-L, OI-L).
Frequency reference by the local
potentiometer can be monitored..
0.1 ~ 3000sec
0.1 ~ 999.9 --- by 0.1sec
Minimum
1000 ~ 3000 --- by 1sec
setting range
0.1~3000sec
0.1 ~ 999.9 --- by 0.1sec
Minimum
1000 ~ 3000 --- by 1sec
setting range
Two options: select codes:
0... Forward run
1... Reverse run
Basic setting functions
setting range : A01∼A65.
Fine tuning functions
Setting range :b01∼b17.
Terminal setting functions
Setting range :C01∼C23
Sensorless vector setting functions
Setting range :H01∼H15.
4-6
Run-
Defaults
time
Edit
volume
setting
O
value
30.0sec
O
30.0sec
O
0
X
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents