N700E INSTRUCTION MANUAL

4. Parameter Code List

About Digital Operator

4.1
4.1.1

Name and contents of each part of Standard-type digital operator

(1) Part name
RUN LED
on when the inverter outputs
the PWM voltage and operating
command is ready
POWER LED
On when the control
powerinput to inverter is on
Display part (LED display)
This part display frequency,
motor current, motor rotation
speed, alarm history,
and setting value.
RUN Key
Press this key to run the
motor. The Run enable
LED must be terminal operation
(2) Operation procedure
① Example that the frequency is set from potentiometer to the standard operator and the equipment
starts running)
STOP/RESET Key
This key is used for stopping the motor
or resetting errors.(When either operator
or terminal is selected, this key works.
If the extension function b 15 is used,
this function is void)
FUNCTION Key
This key is used for changing
parameter and command.
Fig.4-1 LED Type Digital Operator
UP/DOWN Key
This key is used to change data and
increase of decrease the frequency
4-1
PRG LED
This LED is on when the
inverter is ready for
parameter editing.
Hz LED / A LED
Display units Hertz/Ampere
LEDs.
Potentiometer
set the inverter output
frequency.(be operated
only when the ramp is ON)
STORE Key
Press the store key to
write the data and
setting value to the memory