N700E INSTRUCTION MANUAL
3.2

Test Run

This is an example of a common connection. Please refer to 4.1 Digital Operator, for the detailed use of the
digital operator.
3.2.1
To input the operation setting and the frequency setting from the terminal
control
(Procedure)
(1) Please make sure that the connections are secured correctly.
(2) Turn the MCCB on to supply power to the inverter.
(The LED "POWER" on the operator should illuminate)
(3) Set the terminal with the frequency setting selection.
Set A01 as the indication code, press the (FUNC) key once. (Code values are shown)
Set 1(Terminal) with (UP/DOWN) key, press the (STR) key once to set the operation setting for the
operator.(Indication code turns back to A01.)
(4) Set terminal with the operation setting selection.
Set A02 as indication code, press the (FUNC) key once.
Set 1(terminal) with the (UP/DOWN) key, press the (STR) key once to set the operation setting for the
operator.(Indication code turns back to A02.)
(5) Set Monitor mode
When monitoring the output frequency, set indication code to d001, and press the (FUNC) key.
Or when monitoring the operation direction, set indication code to d04, and press the (FUNC) key.
(6) Input starting operation setting.
Turn ON between [FW] and [CM1] of terminal.
Apply voltage [O] and [L] of terminal to start operation.
(7) Input ending operation setting.
Turn OFF between [FW] and [CM1] to slowly stop.
Fig 3-1 Setting diagram from the terminal control