CAME ZLJ24 Installation Manual

CAME ZLJ24 Installation Manual

For 24 v operators
Hide thumbs Also See for ZLJ24:

Advertisement

CONTROL PANEL
319 U 9 8E N
FOR 24 V OPERATORS
ZLJ24
English
EN

Advertisement

Table of Contents
loading

Summary of Contents for CAME ZLJ24

  • Page 1 CONTROL PANEL 319 U 9 8E N FOR 24 V OPERATORS Installation manual ZLJ24 English...
  • Page 2 2.1 Intended use The ZLJ24 control panel is engineered to command 24 V DC automation for swing gates of the Axo-Frog-Ferni-Fast series. The use of this product for purposes other than as described above and installation executed in a manner other than as instructed in this technical manual are prohibited.
  • Page 3 4.1 Dimensions, spans and anchoring holes (mm) 4.2 Main components 1 - Transformer 2 - Card fuse 3 - Accessories fuse 4 - Electrolock fuse 5 - Display 6 - Display lighting adjustment trimmer 230V 230V 7 - Memory roll card connector 8 - AF card connector 9 - R700 card connector 10 - Open contact error - warning LED...
  • Page 4 5 Installation Installation must be carried out by expert qualified personnel and in full observance of regulations in force. 5.1 Preliminary checks Before installing do the following: • Check that the panel’s anchoring point is protected from possible blows, and that the anchoring surface is solid. Also check that the anchoring is done using the appropriate bolts, screws etc.;...
  • Page 5 5) Snap the cover into place onto the hinges. 6) After the adjustments and settings, fix the cover using the provided screws. 6 Electrical connections 6.1 Cable and type and section Type Length of cable Length of cable Length of cable Connections of cable 1 <...
  • Page 6 Signalling devices Movement flashing light (Contact output: 24 Indicator light when gate is open V. - 25 W max.) (contact output: 24 V – 3 W max.). Flashes during the gate’s opening and Indicates that gate leaf is open, and closing phases.
  • Page 7 Gearmotor, mechanical stops M1 - 24 V DC gearmotor featuring delayed action on opening M2 - 24 V DC gearmotor featuring delayed action on closing F1024 FROG-A24 F1024 FROG-A24 F4024 F4024 M1 N1 E1 M2 N2 E2 2 FA1 FC1 FA2 FC2 Gearmotor, encoder M1 - 24 V DC gearmotor featuring delayed action on opening M2 - 24 V DC gearmotor featuring delayed action on closing...
  • Page 8 Confi gure either (N.C.) contacts CX, CY or CZ, input for EN 12978 compliant safety devices DF with DFI connections such as sensitive edges. See CX, CY or CZ input monitor card functions in: - C7 «Open while closing», During gate closing, opening the contact causes inversion of movement until gate is fully open;...
  • Page 9 7 Programming 7.1 Description of display commands Lingua the <...> symbols on the display are for: Italiano -pointing out the currently, selected item The ESC key is for: The ENTER key is for: - exiting the menu; - entering the menu; - cancelling modifications.
  • Page 10 7.3 Menu structure <Deutsch> <English <Francais> > < > ENTER LANGUAGE > > > > <Espanol> <Italiano> > > < FUNCTIONS > ENTER > < Imp. > ENTER See detail of functions on pages 19, 20, 21 and 22 (the “ENCODER” function, appears only if >...
  • Page 11 < Turn on > <Autoclose> ENTER > <No.Motors> <M1+M2> ENTER > <Disabled> > < M2 > > <Maintained Act> ENTER <Disabled> > <Motor type> Frog ENTER > > < Turn on > > FROG-J FERNI <when close > > > AMICO >...
  • Page 12 7.4 Main menu < ENCODER > < LANGUAGE > < FUNCTIONS > < Imp. Run > English Press ENTER It appears only if selected from the “Config.” for 1 second Section in the FUNCTIONS menu. <TIMING ADJ.> < TEST MOT. > <...
  • Page 13 Obstacle detected: when motor is stopped (gate closed or after a total stop command) it prevents any movement if safety devices, such as photocells, detect any obstacles. < LANGUAGE > English <Obstacle Det.> Obstacle Det. FUNCTIONS Disabled < Disabled > Imp.
  • Page 14 Total Stop: this function stops the gate and consequently excludes any automatic closing cycle; for movement to resume, you need to use the keypad or transmitter. Insert safety device on [1-2]; Insert the safety device on [1 -2]; if unused, select “Deactivated” <...
  • Page 15 CZ input: safety contact input can take on the following functions: C1 (re-opening when closing), C2 (re-closing when opening), C3 (partial stop), C4 (obstacle stall), C7 (re-opening when closing, for sensitive edges), C8 (re-closing when opening, for sensitive edges) or, be deactivated. See safety devices on electrical connections. <...
  • Page 16 Endstop: configure the endpoints are normally closed or open contacts. N.B.: this function appears only if selected from the “Config.” function in the FUNCTIONS menu. < LANGUAGE > X 13 English < endstop > endstop FUNCTIONS < > Imp. Run endstop TIMING ADJ.
  • Page 17 B1-B2 output: setting contact B1-B2 to MONO-STABLE or BI-STABLE (switch) mode. X 17 < LANGUAGE > English output B1-B2 < output B1-B2 > < Monostable > Monostable FUNCTIONS > Imp. Run output B1-B2 TIMING ADJ. < Bistable > USERS 7.7 Gate-Run Setting Menu Number of motors: setting the number of motors, either one or two, depending on the number of gate leaves installed on the system.
  • Page 18 % speed of deceleration: setting up the deceleration speed, expressed as a percentage between 10% and 50%. < LANGUAGE > English FUNCTIONS low Down Spd < low Down Spd > Imp. Run < > TIMING ADJ. low Down Spd USERS <...
  • Page 19 Deceleration time: gate leaf deceleration time before each endpoint. The time can be set anywhere between 0” to 30”. N.B.: this function only appears if the decelerations and Fcap-RallCh. are selected. < LANGUAGE > English FUNCTIONS Slow down time < Slow down time > <...
  • Page 20 Encoder Deceleration: this activates the opening and closing deceleration starting points. FUNCTIONS Imp. Run < Slow run Enc > Slow run Enc < > ENCODER TIMING ADJ. Slow run Enc < > USERS INFO M1 opening deceleration%: this adjusts the (M1) first motor’s deceleration starting point before the opening endpoint. The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run).
  • Page 21 M2 closing deceleration %: this adjusts the (M2) second motor’s deceleration starting point before the closing endpoint. The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 32. N.B.: this function appears only if it is activated in the “decel.
  • Page 22 M1 Acc. Opening %: sets the point at which the gate begins adjusting deceleration before making contact with the opening endpoint of the fi rst motor (M1). The beginning point of adjustment is calculated as a percentage ( between 1% and 15%) of the total gate run time. See illustration on page 32.
  • Page 23 7.9 Time setting menu Automatic closing: to set the waiting time when gate is in the open position. Once this time is elapsed, the gate closes automatically. The waiting time can be set to between 0” and 300”. Imp. Run ENCODER ACT.
  • Page 24 M2 delayed closing: the waiting time of the (M2) second gate leaf, unlike the (M1) first one, after each closing command. the waiting time can be set to between 0” and 60”. Imp. Run ENCODER < Cl. Delay M2 > Cl.
  • Page 25 Partial opening: opening time of the second (M2) gate leaf. The time can set between 5 and 60 seconds. Imp. Run ENCODER < Slow down time > Slow down time < > TIMING ADJ. USERS Slow down time INFO < >...
  • Page 26 Related Function: to change the function assigned to the user. < Related Func > Choose User FUNCTIONS < 001:--001-- > Imp. Run ENCODER ENTER Choose User USERS < 002:--002-- > Rel a ted Func. Rel a ted Func. ENTER <2-7> <confi r m? (yes) >...
  • Page 27 : 2.0 Imp. Run < Standby Msg. > < System Reset > ENCODER USERS - WWW.CAME.IT INFO ZLJ24 TEST MOT. TEST MOT. 7.12 Motor test menu MOT TEST.: the MOT test checks that gearmotors are rotating in the proper direction.
  • Page 28 7.13 Decoding card Connect the required cards (R700, AF43S) to insert, change, remove and command the operator via transmitter, card or transponder. Insert the memory roll to save and load all setting including users registered by another card. R700 Card R700 CANCELLI AUTOMATICI LT001...
  • Page 29 7.14 Inputting users N.B.: Before proceding, remove the memory roll card. 1) From the Users 2) Select “ confirm menu, select “Add (yes)” and press Add User Add User User”. ENTER key to confirm. confirm? (yes) Press ENTER to confirm. 3) Choose which 4) ..
  • Page 30 7.16 Changing code 1) From the Users menu, choose Mod. Code Choose User 2) Choose the user “Mod. Code”. name for which you 001:--U001-- Press ENTER to Choose User wish to change the confirm. code and press ENTER 002:--U002-- to confirm. 3) ..
  • Page 31 7.18 Gate run calibration N.B. before calibrating the gate run, check that the manoeuvring area is free of any obstacles and check the proper direction of rotation of the gearmotors. (para. 7.11) 1) From the Encoder 2) Select “confirm Set Encoder menu, select “Adjust Set Encoder (yes) and press ENTER...
  • Page 32 7.20 Exemple des zones et des points de ralentissement et de déplacement pour dispositif encodeur. N.B. : les zones de la course et les points de ralentissement et de déplacement sont testés selon les paramètres des Normes Techniques EN12445 et EN12453 pour la compatibilité des forces d’impact développées par le vantail en mouvement. A = Area of movement at normal speed B* = Run zone at slow-down speed C = Encoder intervention zone with movement inversion...
  • Page 33 UNI EN ISO 14001 standard to ensure environmental protection. Please continue our eff orts to protect the environment—which CAME considers one of the cardinal elements in the development of its Please continue our eff orts to protect the environment—which CAME considers one of the cardinal elements in the development of its operational and market strategies—simply by observing brief recommendations as regards disposal:...
  • Page 36 HU • A vállalatra, termékeire és a műszaki szervizre vonatkozó minden további információért az Ön nyelvén: HR • Za sve dodatne informacije o poduzeću, proizvodima i tehničkoj podršci: UK • Для отримання будь-якої іншої інформації про компанію, продукцію та технічну підтримку: www. came.com www. came.com...

Table of Contents