Before you call Service:

error
Water dripping out of
the unit's door.
Noise is heard in the
cooking cabinet while
the unit is in use.
Cooking cabinet light
not working.
Low water
"OPEn H2O" appears
on the display.
Water running out of
the bottom of the unit
102 / 107
possible cause
Door is not closed
correctly.
Door seal is worn or
damaged.
Air baffles, hanging
racks, etc., are not
fixed correctly.
 
Halogen lamp is
defective.
Water tap closed
Water intake filter on
the unit is clogged.
The unit is not level
Drain is blocked
Rectification
If the door is closed correctly, the door
handle will point down on floor units.
Replace the door seal (see the
"Maintenance" section of the manual).
Care instructions for a maximum service
life:
- At the end of production, always
clean the door seal thoroughly with a
damp cloth.
- If lots of grilled products are cooked
(considerable build-up of grease),
then the door seal must also be
cleaned with a damp cloth between
cycles.
- If the unit is to be operated for a
long time without products, we
recommend that the cooking cabinet
temperature should not exceed 180
°C.
Fix the air baffles and hanging racks
correctly in the cooking cabinet.
 
Replace the lamp (see the
"Maintenance" section of the manual).
Open the water tap
Check and clean the filter. To do this:
Close the water tap, unscrew the water
intake on the unit, then remove and
clean the filter in the water intake. Insert
the filter, connect the water intake and
check for leaks.
Level the unit using a spirit level (see
Installation Manual).
Remove and clean the outlet (HT pipe)
on the back of the unit. Blockages can
occur if products with a high proportion