Combination mode

The two operating modes "steam" and "dry heat" are combined. This combination creates a
hot humid cabinet climate for especially intensive cooking. You can set the cooking cabinet
temperature from 30 °C to 300 °C . You can set the cooking cabinet climate if necessary.
Cooking methods: Roasting, baking, finishing.
step
1
2
3
4
5
6
5
6
info/button
instructions
Choose the "combination" mode.
To preheat, turn the selection button anti-
clockwise as far as it will go. "PreEH" is shown
on the display. The end of preheating is
indicated by an acoustic signal and "LoAd" on
the display.
Set the required temperature.
Select the required cooking cabinet humidity or
work with the default setting.
Press the button to set the cooking time.
Set the required cooking time. For continuous
operation, please turn the selection button
clockwise as far as it will go.
Or alternatively press the "core temperature"
button and set the required core temperature.
Choose the required core temperature.