Building services - steam generator descaling

The steam generator must be descaled manually on a regular basis.
We recommend the following descaling intervals
based on 8 hours' steaming per day:
- up to 18 °dH (to 3.2 mmol/litres) at least 1x annually
- up to 24 °dH (to 4.3 mmol/litres) at least 2x annually
- over 24 °dH (to 4.3 mmol/litres) at least 3x annually
These recommended descaling intervals may vary from the approximate values given above,
depending on the composition of the water (e.g. minerals).
You need:
Electric descaler pump - article no.: 60.70.409
Descaler, 10 litre canister – article no.: 6006.0110
Heavier limescale deposits in the steam generator can only be removed by the Service
Technician.
If the steam generator has a heavier build up of limescale, the "Calc Infor" function will be
displayed at the end of the CleanJet
You can find more information on this in the descaling display sub-section in this operating
manual.
step
1
2
90 / 107
cleaning programme.
®
info/button
instructions
Select "Prog/Clean | Start".
Close the cooking cabinet door.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CombiMaster Plus CMP 61 and is the answer not in the manual?

Questions and answers

Kerry Whitehead
April 20, 2025

We don’t have a basket inside our oven for the tablets. What do we do?

User image 68053a5fdb7d6
1 comments:
Mr. Anderson
May 10, 2025

If there is no basket inside the Rational CombiMaster Plus CMP 61 oven for the tablets, remove the tablets before starting operation to avoid a fire risk.

This answer is automatically generated

Subscribe to Our Youtube Channel

Table of Contents

Save PDF