Building services - steam generator descaling
step
17
18
19
20
Aborting the descaling process
If necessary you can discontinue the descaling process.
 
Before filling with descaling fluid
step
1
2
After filling with descaling fluid
The abort programme lasts approx. 20 minutes.
94 / 107
info/button
info/button
instructions
Close the cooking cabinet door. The length of
the descaling phase is displayed.
The steam generator is automatically rinsed
several times. The appliance then automatically
switches to Steam.
"End" appears on the display when descaling is
complete.
Exit the descaling process by selecting a
cooking mode. Your appliance is now ready for
cooking again.
instructions
Hold down the core temperature button for 10
seconds.
"End" now appears in the cooking time/core
temperature display. Your appliance is now
ready for cooking again.