DIN-Rail Mounting
The aluminum DIN-Rail attachment plate should already be fixed to the back
panel of the IE-SW-PL09M-5GC-4GT when you take it out of the box. If you
need to reattach the DIN-Rail attachment plate to the switch, make sure the
stiff metal spring is situated towards the top, as shown in the following
figures.
STEP 1—Insert the top of the
DIN-Rail into the slot just below the
stiff metal spring.
To remove the device from the DIN-Rail, simply reverse Steps 1 and 2 above.

Wiring Requirements

WARNING
Do not disconnect modules or wires unless power has been
switched off or the area is known to be non-hazardous. The
devices may only be connected to the supply voltage shown on
the type plate. The devices are designed for operation with a
Safety Extra-Low Voltage. Thus, they may only be connected to
the supply voltage connections and to the signal contact with the
Safety Extra-Low Voltages (SELV) in compliance with IEC950/
EN60950-1/ VDE0805.
ATTENTION
This unit is a built-in type. When the unit is installed in another
piece of equipment, the equipment enclosing the unit must
comply with fire enclosure regulation IEC 60950-1/EN60950-1
(or similar regulation).
ATTENTION
Safety First!
Be sure to disconnect the power cord before installing and/or
wiring your Weidmüller Ethernet Switch.
Calculate the maximum possible current in each power wire and
common wire. Observe all electrical codes dictating the
maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring could
overheat, causing serious damage to your equipment.
STEP 2—The DIN-Rail attachment
unit will snap into place as shown in
the following illustration.