Wiring Requirements - Weidmuller IE-SW-VL09T-6TX-3SC Hardware Installation Manual

Value line
Table of Contents

Advertisement

2
c. A 4mm
conductor must be used when connect
grounding screw is utilized.
d. PROVISIONS SHALL BE MADE, EITHER IN EXTERNAL TO THE
APPARATUS, TO P
REVENT THE RATED VOLTAGE BEING
EXCE
EDED BY THE TRANSIENTS DISTURBANCES OF MORE
THAN 40 %.
Wiring Requirem
WARNING
Do not disconnect modules or wires unless the power supply has
been switched off or the area is known to be non-hazardous. The
devices may only be connected to the supply voltage shown on
the type plate.
The devices are designed for operation with a Safety Extra-Low
Voltage. Thus, they may only be connected to the supply voltage
connections and to the signal contact with the Saf
Voltages (SELV) in compliance with IEC950/ EN
VDE0805.
WARNING
Substitution of components may impair suitability for Class I,
Division 2, and Zone 2. These devices must be supplied by an
SELV source as defined in Low Voltage Directive 73/23/EEC
and 93/68/EEC.
WARNING
This unit is a built-in type.
piece of equipment, th
comply with fire en
closure regulation IEC 60950/EN60950 (or
similar regulation).
WARNING
Safety First!
Be sure to disconnect the power cord before installing and/or
wiring your Ethernet Switch.
Calculate the maximum possible current in each power wire and
common
wire. Observe all electrical codes dictating
maximu
m current allowable for each wire size.
If the current goes above the maximum ratin
overheat, causing serious damage
You should also pay attention to the following items:
Use separate paths to route wiring for power and devices. If power wiring
and device wiring paths must cross, make sure the wires are perpendicular
at
the intersection point.
N
OTE: Do not run signal or
communications wiring and power wiring in
the same wire conduit. To avoid interference, wires with different signal
characteristics should be routed separately.
ion to the external
ents
ety Extra-Low
60950/
When the unit is installed in another
e equipment enclosing the unit must
the
gs, the wir
to your equip
ment.
- 6 -