Operating Your Heater - Procom ML200HBA Owner's Operation And Installation Manual

Blue flame vent-free propane/lp gas space heater
Table of Contents

Advertisement

CHECKING GAS
CONNECTIONS
WARNING:
Test all gas
piping and connections for leaks after
installing or servicing. Correct all
leaks at once.
WARNING: Never use an open
flame to check for a leak. Apply a
mixture of liquid soap and water
to
all
joints. Bubbles forming
show a leak. Correct all
once.
Pressure Testing Gas Supply
Piping System
Test Pressures In Excess Of
1/2 PSIG (3.5 K Pa)
1. Disconnect appliance with its
appliance
main
(control valve) and equipment
shutoff valve from gas supply
piping system. Pressures in
excess of 1/2 psig will damage
heater regulator.
2. Cap off open end of gas pipe
where equipment shutoff valve
was connected.
3. Pressurize
supply
s y s t e m
b y
e i t h e r u s i n g
compressed
air
propane/LP supply tank valve.
4. Check all joints of gas supply
piping system. Apply mixture of
liquid soap and water to gas
joints. Bubbles forming show
a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment
shutoff valve to gas supply. Check
reconnected fittings for leaks.
Test Pressures Equal To or
Less Than 1/2 PSIG (3.5 K Pa)
1. Close equipment shutoff valve
(see Figure 15).
2. Pressurize supply piping system
by either using compressed air
or opening propane/LP supply
tank valve.
3. Check all joints from gas meter to
equipment
shutoff
Figure 16).Apply mixture of liquid
soap and water to gas joints.
Bubbles forming show a leak.
4. Correct all leaks at once.
INSTALLATION
Pressure Testing Heater Gas
Connections
1. Open equipment shutoff valve
(see Figure 15).
2.
Open propane/LP supply tank
valve.
3. Make
heater is in the OFF position.
4. Check all joints from equipment
shutoff valve to control valve
leaks at
(see Figure 16 ). Apply mixture of
liquid soap and water to gas
joints. Bubbles forming show
a leak.
5. Correct all leaks at once.
6. Light
Heater, pages 10 and 11 for
gas
valve
thermostat models or page 12
for non-thermostat models).Check
the rest of the internal joints for
leaks.
7. Turn off heater (see To Turn Off
Gas To Appliance, page 11 for
thermostat models or page
12 for non-thermostat models).
8.
Replace lower front panel.
piping
or
opening
Figure 15 -Equipment Shutoff Valve
Figure 16 -Checking Gas Joints
valve (see
sure
control
knob
heater
(see Operating
1 0

OPERATING YOUR HEATER

THERMOSTAT MODELS
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not
follow
these
of
exactly, a fire or explosion may
r e s u l t
c a u s i n g
damage,
personal
loss of life.
A. When lighting the pilot, follow ,
these instructions exactly.
B. BEFORE LIGHTING smell all
around the appliance area for
gas. Be sure to smell next to
the floor because some gas is
heavier than air and will settle
on the floor .
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch;
do not use any phone in your
building.
Immediately
supplier from a neighbor's
phone.
Follow
supplier's instructions.
If
you
cannot
gas supplier, call
department.
C. Use only your hand to push in
or turn the gas control knob.
Never use tools. If the knob
will not push in or turn by
hand, don't try to repair it, call
a qualified service technician or
gas supplier. Force or attempted
repair may result in a fire or
explosion.
D. Do not use this appliance if any
part has been under water.
Immediately call a qualified
service technician to inspect
the appliance and to replace
any part of the control system
and any gas control which has
been under water.
instructions
p r o p e r t y
injury
or
call
your
gas
the
gas
reach
your
the fire