Proper Ventilation & Fresh Air; Providing Adequate Ventilation - Procom ML200HBA Owner's Operation And Installation Manual

Blue flame vent-free propane/lp gas space heater
Table of Contents

Advertisement

FRESH AIR FOR
COMBUSTION AND
VENTILATION
WARNING: This heater
shall not be installed in a
confined space or unusually
tight
construction
provisions are provided for
adequate
combustion
v e n t i l a t i o n
a i r .
f o l l o w i n g
i n s t r u c t i o n s
insure proper fresh air for this
and
other
fuel-burning
appliances in your home.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from
National Fuel Gas Code. NFPA 54/
ANS Z223.1, Section 5.3. Air for
Combustion and Ventilation. All
spaces in homes fall into one of
the three following ventilation
classifications:
1.
Unusually Tight Construction
2.
Unconfined Space
3.
Confined Space
The information on pages 4
through 6 will help you classify
your space and provide adequate
ventilation.
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Determining if you have a Confined or Unconfined Space*
Use this worksheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways
or ventilation grills between the rooms.
1. Determine the volume of the space (length
×
×
Length
Width
Height=
Example: Space size20ft. (length)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these
rooms to the total volume of the space.
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
(volume of space)
Example: 2560 cu. ft. (volume of space)
WARNING: If the area in which the heater may be operated is smaller than that defined as an
unconfined space or if the building is of unusually tight construction, provide adequate combustion and
ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3
or applicable local codes.
Unusually Tight Construction
The air that leaks around doors and
windows may provide enough fresh
air for combustion and ventilation.
However, in buildings of unusually
tight construction, you must provide
additional fresh air.
Unusually tight construction is
unless
defined as construction where:
a. walls and ceilings exposed to
and
the outside
R e a d
t h e
continuous water vapor retarder
t o
with a rating of one per m (6
kg per pa-sec-m
openings gasketed or sealed and
b. weather
added on openable windows and
doors and
c. caulking or sealants are applied
to areas such as joints around
window and door frames, between
sole plates and floors, between
wall-ceiling joints, between wall
panels, at penetrations for plumbing,
electrical, and gas lines, and at
other openings. If your home meets
all of the three criteria above, you
must provide additional fresh air.
See Ventilation Air from Outdoors,
page 6.
meet all of the three criteria above
see Determining Fresh-Air Flow for
Heater Location, page 5.
cu.ft. (volume of space)
×
16ft. ( width)
÷
50 cu. ft.=(Maximum Btu/Hr the space can support)
÷
50 cu.ft.=51.2 or 51.200(maximum Btu/Hr the space can support)
atmosphere
have
×
2
)
or less with
stripping
has
If your home does not
×
×
width
height).
×
8ft. (ceiling height)=2560cu. ft. (volume of space)
4
Confined and
Unconfined Space
The National Fuel Gas Code ANS
Z223.1 defines a confined
as a space whose volume is less
than 50 cubic feet per 1,000 Btu per
3
h o u r ( 4 . 8 m
aggregate input rating of all
appliances installed in that space
and an unconfined space as
a
space whose volume is not less
than 50 cubic feet per 1,000 Btu per
10
-11
3
h o u r ( 4 . 8 m
aggregate input rating of all
appliances installed in that space.
been
Rooms communicating directly with
t h e
s p a c e
appliances are installed*, through
openings not furnished with doors,
are considered a part of the
unconfined space.
This heater shall not be installed in
a confined space or unusually tight
construction unless provisions are
provided for adequate combustion
and ventilation air.
*
Adjoining rooms are communicat-
ing only if there are doorless pas-
sageways
or
between them.
space
p e r k w )
o f
t h e
a
p e r k w )
o f
t h e
i n
w h i c h
t h e
ventilation
grills