Troubleshooting - Procom ML200HBA Owner's Operation And Installation Manual

Blue flame vent-free propane/lp gas space heater
Table of Contents

Advertisement

OBSERVED PROBLEM
B u r n e r ( s ) d o e s n o t l i g h t a f t e r
ODS/pilot is lit.
Delayed ignition of burner(s).
Burner backfiring during combustion.
Yellow
flame
during
combustion.
Slight smoke or odor during
initial operation.
Heater produces a whistling noise
when burner is lit.
Heater produces a clicking/ticking
noise just after burner is lit or
shut off.
White powder residue forming within
burner box or on adjacent
walls or furniture.

TROUBLESHOOTING

POSSIBLE CAUSE
1. Burner orifice is clogged.
2. Burner orifice diameter is too small
3. Inlet gas pressure is too low.
1. Manifold pressure is too low.
2. Burner orifice is clogged.
1. Burner
damaged.
2. Burner damaged.
3. Gas regulator defective.
1. Not enough air.
burner
2. Gas regulator defective.
3. Inlet gas pressure is too low.
1. Residues from manufacturing
processes.
1. Turning control knob to HI position
when burner is cold.
2. Air in gas line.
3. Air
passageways
blocked.
4. Dirty or partially clogged burner
orifice.
1. Metal expanding while heating or
contracting while cooling.
1. When
furniture polish, wax, carpet
cleaners,
powder residue.
Continued
orifice
is clogged
or
on
heater
heated,
vapors
from
etc. turn into white
1 5
REMEDY
1. Clean burner orifice (see Cleaning
and Maintenance, page 13) or
replace burner orifice.
2. Replace burner orifice.
3. Contact local Propane/LP gas company.
1. Contact local Propane/LP gas company.
2. Clean burner (see Cleaning and
Maintenance, page 13) or replace
burner orifice.
1. Clean burner orifice (see Cleaning
and
Maintenance, page 13) or
replace.
2. Replace burner.
3. Replace gas regulator.
1. Check burner for dirt and debris. If
found, clean burner (see Cleaning
and Maintenance, Page 13).
2. Replace gas regulator.
3. Contact local propane/LP gas company.
1. Problem will stop after a few hours
of operation.
1. Turn control knob to LO position
and let warm up for a minute.
2. Operate burner until air is removed
from line. Have gas line checked
by local Propane/LP gas company.
3. Observe
minimum
clearances (Figure 4, p7).
4. Clean burner (see Cleaning and
maintenance, Page13) or replace
burner orifice.
1. This
is
common with most
heaters. If noise
contact qualified service person
1. Turn
heater
off
furniture
polish,
cleaner or similar products.
installation
is
excessive,
when
using
wax,
carpet

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ml200tbaMl300hbaMl300tba